Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Our goal was to analyze radiology report text for chest radiographs (CXRs) to identify imaging findings that have the most impact on report length and complexity. Identifying these imaging findings can highlight opportunities for designing CXR AI systems which increase radiologist efficiency. We retrospectively analyzed text from 210,025 MIMIC-CXR reports and 168,949 reports from our local institution collected from 2019 to 2022. Fifty-nine categories of imaging finding keywords were extracted from reports using natural language processing (NLP), and their impact on report length was assessed using linear regression with and without LASSO regularization. Regression was also used to assess the impact of additional factors contributing to report length, such as the signing radiologist and use of terms of perception. For modeling CXR report word counts with regression, mean coefficient of determination, R, was 0.469 ± 0.001 for local reports and 0.354 ± 0.002 for MIMIC-CXR when considering only imaging finding keyword features. Mean R was significantly less at 0.067 ± 0.001 for local reports and 0.086 ± 0.002 for MIMIC-CXR, when only considering use of terms of perception. For a combined model for the local report data accounting for the signing radiologist, imaging finding keywords, and terms of perception, the mean R was 0.570 ± 0.002. With LASSO, highest value coefficients pertained to endotracheal tubes and pleural drains for local data and masses, nodules, and cavitary and cystic lesions for MIMIC-CXR. Natural language processing and regression analysis of radiology report textual data can highlight imaging targets for AI models which offer opportunities to bolster radiologist efficiency.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10976950 | PMC |
http://dx.doi.org/10.1007/s10278-023-00927-5 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!