Influence of glazing and aging on the marginal, axial, axio-occlusal, and occlusal fit of 3-unit monolithic zirconia restorations fabricated using additive and subtractive techniques.

J Prosthet Dent

Associate Professor, Department of Prosthetic Dentistry, Faculty of Dentistry, Near East University, Nicosia, North Cyprus. Electronic address:

Published: April 2024

Statement Of Problem: Studies are sparse on how glazing and aging influence the fit of additively fabricated monolithic zirconia restorations.

Purpose: The purpose of this in vitro study was to assess the effect of glazing and aging on the fit of 3-unit monolithic zirconia restorations fabricated using different techniques.

Material And Methods: A total of 32 monolithic zirconia restorations were fabricated for a typodont model by using 4 distinct techniques (subtractive fabrication [SF], stereolithography [SLA], digital light processing [DLP], and lithography-based ceramic manufacturing [LCM]). The silicone replica approach was adopted to measure the discrepancy values for premolar and molar abutments after sintering, glazing, and 1 year of aging. The silicone replicas were sliced into mesiodistal and buccopalatal cross-sections, and digital micrographs of the cross-sections were made with a ×80 stereomicroscope. An inherent measuring program was run to record the discrepancy values (µm). Repeated-measures 2-way ANOVAs with the Bonferroni post hoc test were used to statistically analyze the acquired data. (α=.05).

Results: From the repeated measures 2-way ANOVAs, both the glazing×fabrication technique and the aging×fabrication technique interactions were not statistically significant (P>.05). Glazing significantly influenced premolar abutment marginal (P=.022) and occlusal (P=.007) discrepancy values, as well as molar abutment marginal discrepancy values (P=.047). Aging had a statistically significant effect on premolar abutment marginal (P=.008) and occlusal (P=.011) discrepancy values, as well as molar abutment occlusal discrepancy values (P=.039). In both the glazing and aging data, for all areas of interest, statistically significant differences were detected among the fabrication techniques (P<.05). The LCM group had the lowest discrepancy values, followed by the SLA, SF, and DLP groups.

Conclusions: The LCM and SLA groups outperformed the other groups in terms of fit accuracy. The glazing and aging procedures altered the discrepancy values. The marginal discrepancy values of all groups were below the threshold of clinical acceptability (<120 µm).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prosdent.2024.01.010DOI Listing

Publication Analysis

Top Keywords

discrepancy values
24
glazing aging
16
monolithic zirconia
16
zirconia restorations
12
restorations fabricated
12
abutment marginal
12
fit 3-unit
8
3-unit monolithic
8
2-way anovas
8
premolar abutment
8

Similar Publications

End-Point Affinity Estimation of Galectin Ligands by Classical and Semiempirical Quantum Mechanical Potentials.

J Chem Inf Model

January 2025

Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Gilead Sciences & IOCB Research Centre, Flemingovo nám. 2, 166 10 Prague, Czech Republic.

The use of quantum mechanical potentials in protein-ligand affinity prediction is becoming increasingly feasible with growing computational power. To move forward, validation of such potentials on real-world challenges is necessary. To this end, we have collated an extensive set of over a thousand galectin inhibitors with known affinities and docked them into galectin-3.

View Article and Find Full Text PDF

Background: Delinquent behavior in adolescence is a prevalent issue, often associated with difficulties across multiple life domains, which in turn perpetuates negative life outcomes. While current treatment programs show partial success in improving behavioral changes and reducing recidivism, comprehensive conclusions regarding the overall efficacy of these interventions have yet to be established. In forensic outpatient settings, the discrepancy between adolescents' limited emotional awareness and the predominant emphasis on cognitive reflection, combined with low treatment adherence, may be factors that undermine treatment efficacy.

View Article and Find Full Text PDF

Our goal is to improve Project Management (PM) profitability and reduce discrepancies in information among stakeholders, which can result in conflicts. This will be accomplished by incorporating Earned Value Management (EVM) with the Income Statement and incorporating earnings before interest, tax, depreciation, and amortization (EBITDA) with the work breakdown structure (WBS). These incorporations will streamline information sharing between PM, other management professionals, and the stakeholders, ultimately fostering the application of PM within broader business and management contexts.

View Article and Find Full Text PDF

Clinical Manifestations.

Alzheimers Dement

December 2024

Sorbonne Université, Paris Brain Institute - Institut du Cerveau - ICM, Inserm U1127, CNRS UMR 7225, AP-HP - Hôpital Pitié-Salpêtrière, Paris, France.

Background: Anosognosia, a hallmark of Alzheimer's disease (AD), manifests as a gradual decline in disease awareness, yet its neural correlates remain unclear. This study investigates how amyloid accumulation, glucose hypometabolism and cortical atrophy relate to cognitive awareness across the AD continuum. Both the pathological processes and the brain regions involved were studied.

View Article and Find Full Text PDF

Aim: The aim of this study was to compare the marginal accuracy of polyetheretherketone (PEEK) and zirconia copings fabricated using computer-aided design/computer-aided manufacturing (CAD/CAM) technology, and to assess the impact of their material properties on accuracy when produced with a 4-axis milling system under controlled conditions.

Settings And Design: The study employed an in vitro design with a stainless steel die model featuring a 6 mm axial wall height, a 6-degree total occlusal convergence, and a radial shoulder finish line.

Materials And Methods: Thirty stone dies were created from silicone impressions of the metal die and poured using type-IV dental stone.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!