A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Influence of the Intracranial Contents on the Head Motion under Bone Conduction. | LitMetric

Influence of the Intracranial Contents on the Head Motion under Bone Conduction.

Audiol Neurootol

Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Zurich, University of Zurich, Zurich, Switzerland.

Published: August 2024

Introduction: The mechanism of non-osseous bone conduction pathways, involving the intracranial contents (ICC) of the skull, is still not well understood. This study aimed to investigate the influence of the ICC on the skull bone wave propagation, including dependence on stimulation location and coupling.

Methods: Three Thiel-embalmed whole-head cadaver specimens were studied before and after the removal of the ICC. Stimulation was via the electromagnetic actuators from commercial bone conduction hearing aids. Osseous pathways were sequentially activated by mastoid, forehead, and bone-anchored hearing aid location stimulation via a 5-Newton steel headband or percutaneously implanted screw. Non-osseous pathways were activated by stimulation on the eye and dura via a 5-Newton steel headband and a custom-made pneumatic holder, respectively. Under each test condition, the 3D motion of the superior skull bone was monitored at ∼200 points.

Results: The averaged response of the skull surface showed limited differences due to the removal of the ICC. In some isolated cases, the modal pattern on the skull surface showed a trend for an upshift (∼1/2 octave) in the observed natural frequencies for drained heads. This was also consistent with an observed trend for an upshift in the transition frequency in the estimated deformation across the lateral surfaces of the temporal bones. Such changes were consistent with the expected reduction in mass and damping due to the absence of the ICC.

Conclusion: Overall, the ICC affect to a limited extent the motion of the skull bone, with a limited trend for a reduction of its natural frequencies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11309072PMC
http://dx.doi.org/10.1159/000537724DOI Listing

Publication Analysis

Top Keywords

bone conduction
12
skull bone
12
intracranial contents
8
icc skull
8
removal icc
8
5-newton steel
8
steel headband
8
skull surface
8
trend upshift
8
natural frequencies
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!