Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
(1) Background: Proton therapy, a precise form of radiation treatment, can be significantly affected by variations in bowel content. The purpose was to identify the most beneficial gantry angles that minimize deviations from the treatment plan quality, thus enhancing the safety and efficacy of proton therapy for Wilms' tumor patients. (2) Methods: Thirteen patients with Wilms' tumor, enrolled in the SJWT21 clinical trial, underwent proton therapy. The variations in bowel gas were systematically monitored using daily Cone Beam Computed Tomography (CBCT) imaging. Air cavities identified in daily CBCT images were analyzed to construct daily verification plans and measure water equivalent path length (WEPL) changes. A worst-case scenario simulation was conducted to identify the safest beam angles. (3) Results: The study revealed a maximum decrease in target dose (ΔD100%) of 8.0%, which corresponded to a WEPL variation (ΔWEPL) of 11.3 mm. The average reduction in target dose, denoted as mean ΔD100%, was found to be 2.8%, with a standard deviation (SD) of 3.2%. The mean ΔWEPL was observed as 3.3 mm, with an SD of 2.7 mm. The worst-case scenario analysis suggested that gantry beam angles oriented toward the patient's right and posterior aspects from 110° to 310° were associated with minimized WEPL discrepancies. (4) Conclusions: This study comprehensively evaluated the influence of bowel gas variability on treatment plan accuracy and proton range uncertainties in pediatric proton therapy for Wilms' tumor.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10854738 | PMC |
http://dx.doi.org/10.3390/cancers16030642 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!