A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluating the Impact of Bowel Gas Variations for Wilms' Tumor in Pediatric Proton Therapy. | LitMetric

(1) Background: Proton therapy, a precise form of radiation treatment, can be significantly affected by variations in bowel content. The purpose was to identify the most beneficial gantry angles that minimize deviations from the treatment plan quality, thus enhancing the safety and efficacy of proton therapy for Wilms' tumor patients. (2) Methods: Thirteen patients with Wilms' tumor, enrolled in the SJWT21 clinical trial, underwent proton therapy. The variations in bowel gas were systematically monitored using daily Cone Beam Computed Tomography (CBCT) imaging. Air cavities identified in daily CBCT images were analyzed to construct daily verification plans and measure water equivalent path length (WEPL) changes. A worst-case scenario simulation was conducted to identify the safest beam angles. (3) Results: The study revealed a maximum decrease in target dose (ΔD100%) of 8.0%, which corresponded to a WEPL variation (ΔWEPL) of 11.3 mm. The average reduction in target dose, denoted as mean ΔD100%, was found to be 2.8%, with a standard deviation (SD) of 3.2%. The mean ΔWEPL was observed as 3.3 mm, with an SD of 2.7 mm. The worst-case scenario analysis suggested that gantry beam angles oriented toward the patient's right and posterior aspects from 110° to 310° were associated with minimized WEPL discrepancies. (4) Conclusions: This study comprehensively evaluated the influence of bowel gas variability on treatment plan accuracy and proton range uncertainties in pediatric proton therapy for Wilms' tumor.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10854738PMC
http://dx.doi.org/10.3390/cancers16030642DOI Listing

Publication Analysis

Top Keywords

proton therapy
20
wilms' tumor
16
bowel gas
12
pediatric proton
8
variations bowel
8
treatment plan
8
therapy wilms'
8
worst-case scenario
8
beam angles
8
target dose
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!