A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Novel radiologic indices for stem type decision in total hip arthroplasty in patients with metaphyseo-diaphyseal mismatched Dorr A proximal femur. | LitMetric

Background: In metaphyseo-diaphyseal (M-D) mismatched Dorr A femurs, it is difficult to achieve proper fixation with a type 1 stem. Proper interpretation of the geometry of the femur is integral at the preoperative stage in an M-D mismatched femur, but there has been a scarcity of studies on the radiologic indices. Therefore, we analyze the previous radiologic indices and suggest the novel ones for M-D mismatched femurs.

Methods: Our study was a retrospective review of preoperative radiographs of patients who underwent total hip arthroplasty with the smallest type 1 stem or with type 3 C stem at a single institution from July 2014 to March 2022. A Type 3 C stem was used when the smallest type 1 stem failed to achieve metaphyseal fixation. One hundred twenty-six patients were categorized into two main groups. Canal-flare index, canal-calcar ratio, modified morphological cortical index, and two novel indices (lesser trochanter-to-distal ratio-α and -β [LDR-α and -β]) were assessed on preoperative pelvic radiographs.

Results: Multivariate and ROC analysis demonstrated that high LDR-β (Exp[B]: 485.51, CI: 36.67-6427.97, p < 0.001) was associated with a more mismatched tendency group and had clinically acceptable discriminatory power (AUC: 0.765, CI: 0.675-0.855, p < 0.001) between the two cohorts.

Conclusion: Correct assessment of preoperative femoral morphology would be fundamental in the selection of a suitable stem. The ratio based on 3 cm below the lesser trochanter of the femur seemed crucial. We recommend evaluating the newly described radiological index preoperatively in M-D mismatched Dorr A femur for planning precisely and selecting a proper stem.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10854119PMC
http://dx.doi.org/10.1186/s12891-024-07223-5DOI Listing

Publication Analysis

Top Keywords

radiologic indices
12
m-d mismatched
12
type stem
12
stem type
8
total hip
8
hip arthroplasty
8
mismatched dorr
8
smallest type
8
type 3 c
8
3 c stem
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!