Background: Eye examinations and eyeglasses acquisition are typically integrated into a cohesive procedure in China. We conducted a randomized controlled trial using incognito standardized patient (SP) approach to evaluate the impact of separating eyeglasses sales on the accuracy of final prescription.
Methods: 52 SPs were trained to provide standardized responses during eye examinations, and undergoing refraction by a senior ophthalmologist at a national-level clinical center. SPs subsequently received eye examinations at 226 private optical shops and public hospitals in Shaanxi, northwestern China. The visits were randomly assigned to either control group, where SPs would typically purchase eyeglasses after refraction, or treatment group, where SPs made an advance declaration not to purchase eyeglasses prior to refraction. The dioptric difference between the final prescriptions provided by local refractionists and expert in the better-seeing eye was determined using the Vector Diopteric Distance method, and the completeness of exams was assessed against national standards. Multiple regressions were conducted to estimate the impact of no eyeglasses sales on the accuracy of the final prescription of local refractionists, as well as the completeness of examinations.
Results: Among 226 eye exams (73 in public hospitals, 153 in private optical shops), 133 (58.8%) were randomized to control group and 93 (41.2%) to no eyeglasses sales group. The inaccuracy rate of final prescriptions provided by local refractionists (≥ 1.0 D, experts' final prescription as the reference) was 25.6% in control group, while 36.6% in no-sale group (P = 0.077). The likelihood of providing inaccurate final prescriptions was significantly higher in no-sale group compared to control group (OR = 1.607; 95% CI: 1.030 to 2.508; P = 0.037). This was particularly evident in private optical shops (OR = 2.433; 95% CI: 1.386 to 4.309; P = 0.002). In terms of process quality, the no-sale group performed significantly less subjective refraction (OR = 0.488; 95% CI: 0.253 to 0.940; P = 0.032) and less testing SP's own eyeglasses (OR = 0.424; 95% CI: 0.201 to 0.897; P = 0.025). The duration of eye exams was 3.917 min shorter (95% CI: -6.798 to -1.036; P = 0.008) in no-sale group.
Conclusions: Separating eyeglasses sales from optical care could lead to worse quality of eye care. Policy makers should carefully consider the role of economic incentives in healthcare reform.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10858552 | PMC |
http://dx.doi.org/10.1186/s12889-024-17882-7 | DOI Listing |
BMC Public Health
February 2024
Center for Experimental Economics in Education, Shaanxi Normal University, Xi'an, China.
Background: Eye examinations and eyeglasses acquisition are typically integrated into a cohesive procedure in China. We conducted a randomized controlled trial using incognito standardized patient (SP) approach to evaluate the impact of separating eyeglasses sales on the accuracy of final prescription.
Methods: 52 SPs were trained to provide standardized responses during eye examinations, and undergoing refraction by a senior ophthalmologist at a national-level clinical center.
Zhonghua Yi Shi Za Zhi
July 2021
Eye Hospital of Shandong First Medical University, Jinan 250021, China School of Ophthalmology, Shandong First Medical University, Jinan 250021, China Eye Hospital of Shandong First Medical University Shandong Eye Museum, Jinan 250021, China.
was finished in the early Qing Dynasty with realism. This painting album described the prosperity in business and everyday life in Suzhou during the late Ming and the early Qing Dynasties. They were drawn and painted retrospectively, ie, the content of the pictures was based on existing paintings handed down.
View Article and Find Full Text PDFPLoS One
September 2021
Centre for Eye Research Ireland, School of Physics and Clinical and Optometric Sciences, Technological University Dublin, Dublin, Ireland.
Purpose: To examine whether data sourced from electronic medical records (EMR) and a large industrial spectacle lens manufacturing database can estimate refractive error distribution within large populations as an alternative to typical population surveys of refractive error.
Subjects: A total of 555,528 patient visits from 28 Irish primary care optometry practices between the years 1980 and 2019 and 141,547,436 spectacle lens sales records from an international European lens manufacturer between the years 1998 and 2016.
Methods: Anonymized EMR data included demographic, refractive and visual acuity values.
Inquiry
October 2021
Center for Experimental Economics in Education, Shaanxi Normal University, Xi'an, China.
Free trial is a widely used business strategy that takes advantage of information asymmetry. However, evidence on what we can learn and how rapidly we can learn from a free trial of health care is limited. This study evaluates the effect of a free trial of eyeglasses on children's 8 items of perception related to eyeglasses use.
View Article and Find Full Text PDFVision Res
May 2020
University of Essex, Department of Psychology, Wivenhoe Park, Colchester CO4 3SQ, United Kingdom. Electronic address:
A masked randomised control design compared the effectiveness of precision ophthalmic tints in improving the recognition of emotion in Autism Spectrum Disorders (ASD). Fourteen children aged 10-14 with ASD and 14 control children matched on verbal and non-verbal IQ, wore spectacles with coloured lenses to complete two tasks that involved the observation of coloured video sequences in which social interactions were depicted. On one occasion (randomly first or second) the coloured lenses provided light of a colour that the child had one month previously selected as optimal for the clarity of text.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!