Mn:PIN-PMN-PT piezocrystal is investigated to determine whether its enhanced energy density makes it a candidate transducer material for power ultrasonics applications. To this end, the electromechanical and vibrational characteristics of a simple configuration of a bolted Langevin transducer (BLT) and then an ultrasonic surgical device, both incorporating Mn:PIN-PMN-PT piezocrystal, are compared with the same transducer configurations incorporating a conventional hard PZT piezoceramic commonly used in high-power ultrasonic transducers. The material properties of Mn:PIN-PMN-PT are determined using a single sample characterisation technique and these are used in finite element analysis (FEA) to design and then fabricate the BLT and ultrasonic surgical device, tuned to the first and second longitudinal modes at 20 kHz respectively. FEA is similarly used for the hard PZT versions. It is found that the superior elastic compliance of Mn:PIN-PMN-PT results in a higher radial piezo-stack deformation than the hard PZT under ultrasonic excitation of the BLT. However, the resulting longitudinal displacement amplitude of the two BLTs and two ultrasonic surgical devices is found to be equal, despite the higher figure of merit (Qk) of those incorporating Mn:PIN-PMN-PT. The electrical impedance is measured at increasing excitation levels to evaluate the quality factor, Q. It is found that damping in the BLT with hard PZT is negligibly affected in the excitation range considered; however, the BLT incorporating Mn:PIN-PMN-PT exhibits a large reduction in Q. These findings indicate that, for measurements in air, the advantages of the high figure of merit of the piezocrystal material are not realised in a high-power transducer due to significantly increased damping at high excitation levels. To compare the vibrational response of the two ultrasonic surgical devices, L-C electrical impedance matching was implemented to maximise the efficiency of energy transfer from the source to the transducer under load. Results suggest that similar responses occurred for the two surgical devices in cutting tests using a low strength bone mimic material. However, the Mn:PIN-PMN-PT device exhibited better performance in cutting through higher strength ex-vivo chicken femur.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ultras.2024.107257 | DOI Listing |
JACC Cardiovasc Interv
December 2024
Department for Angiology, Brandenburg Medical School Theodor Fontane, Campus Clinic Brandenburg, Center for Internal Medicine I, Berlin, Germany; Department of Angiology, Sankt-Gertrauden-Krankenhaus, Berlin, Germany.
Background: Several randomized clinical trials have shown that the composite endpoint of death, stroke, and myocardial infarction (MI) is equivalent between carotid artery stenting and carotid endarterectomy. However, the risk of minor stroke has been consistently higher with carotid artery stenting.
Objectives: The authors sought to evaluate the safety and effectiveness of a novel carotid stent system comprised of a stent, an adjustable integrated embolic filter and a postdilation balloon, in patients at elevated risk for adverse events from carotid endarterectomy.
Sensors (Basel)
December 2024
School of Electrical and Computer Engineering, National Technical University of Athens, 15772 Athens, Greece.
J Cancer Res Ther
December 2024
Department of Ultrasonic Intervention, Eastern Hepatobiliary Surgery Hospital, Second Military Medical University (Naval Medical University), Shanghai, China.
Background: This study investigated the clinical efficacy and prognostic factors of ablative treatment in hepatocellular carcinoma (HCC) patients with and without diabetes mellitus (DM).
Methods: Retrospective data were collected from HCC patients who underwent ablation between January 2016 and December 2019. The baseline clinicopathological characteristics and long-term outcomes, such as overall survival (OS) and recurrence-free survival (RFS), were compared between those with and without DM.
J Transl Med
January 2025
Dental School, The University of Western Australia, 17 Monash Avenue, Nedlands, WA, 6009, Australia.
Background: Treatment of deep carious lesions poses significant challenges in dentistry, as complete lesion removal risks compromising pulp vitality, while selective removal often reduces the longevity of restorations. Herein, we propose a minimally invasive approach using High-Intensity Focused Ultrasound (HIFU) for microscale removal of carious dentine. Concurrently, HIFU's antimicrobial effects against associated cariogenic biofilms and the corresponding thermal and biological impacts on surrounding tissues were investigated.
View Article and Find Full Text PDFNeurocrit Care
January 2025
Department of Health Research, Medical Technology, SINTEF, Trondheim, Norway.
Background: Optic nerve sheath diameter (ONSD) is a promising noninvasive parameter for intracranial pressure (ICP) assessment. However, in the setting of aneurysmal subarachnoid hemorrhage (aSAH), several previous studies have reported no association between ultrasonically measured ONSD and ICP. In this study, we evaluate ONSD in patients with aSAH using a novel method of automated real-time ultrasonographic measurements and explore whether factors such as having undergone surgery affects its association to ICP.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!