Objectives: Aim of this study was to assess survival rates, radiographic, and pink esthetic outcomes of a bone-level-tapered (BLT) implant following immediate or early implant placement.
Materials And Methods: Patients in need of tooth extraction and one implant in the anterior or premolar area were recruited in five centers. Patients were randomly assigned to the immediate or early placement protocol. Implants were restored with all-ceramic crowns cemented to titanium-base-abutments. Radiographic bone levels, implant stability quotient (ISQ), and pink esthetic outcomes were assessed. Data were analyzed descriptively. Level of significance was set at 0.05. Differences between groups were tested using Wilcoxon-signed-rank and Mann-Whitney-U test as nonparametric tests.
Results: A total of 60 patients received 60 BLT implants (Institut Straumann). At 12-months, 59 implants (98.3%) were osseointegrated. The mean distance from implant shoulder to first bone-to-implant contact was 0.15 ± 0.59 mm without significant differences between the groups. Median ISQ values increased from 75.5 to 78.5. A mean buccal recession of 0.1 ± 0.70 mm occurred with no difference between groups. The mean papilla height gain in both groups was 0.5 ± 1.47 mm mesially and 0.4 ± 1.36 mm distally.
Conclusions: After 1 year, immediately and early placed BLT implants exhibit similar bone level changes, ISQ values, and pink esthetic outcomes.
Clinical Significance: The present research contributes to the knowledge on clinical outcomes of immediately and early placed BLT implants restored with buccally microveneered ceramic single crowns out of two different ceramic materials. The research shows that similar esthetic and radiographic outcomes can be reached by means of immediate implant placement compared to the conventional early placement protocol. The improvement of esthetic soft-tissue parameters over time was shown for both implant placement protocols.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/jerd.13206 | DOI Listing |
Acta Odontol Scand
January 2025
Private Practice, Kristianstad, Sweden.
Aims: Little attention has been paid to patients' perception of function and esthetics with single dental implants. The aim of this study was therefore to describe patient-reported function and esthetic outcomes in single dental implants. A second aim was to study the objective esthetics in single dental implants.
View Article and Find Full Text PDFMedicine (Baltimore)
January 2025
Department of Stomatology, Quanzhou First Hospital Affiliated to Fujian Medical University, Quanzhou, Fujian, China.
The interdental papilla is closely associated with oral health and dental aesthetics. Interproximal papilla is an essential component of pink aesthetics as well as an indispensable prerequisite for the health of oral tissues. The loss of papillary height not only considerably affects final esthetic results, but also brings a series of periodontal complications.
View Article and Find Full Text PDFObjectives: To: 1) analyze possible differences in the CIEDE2000 lightness, chroma and hue of the gingiva at the free gingival margin (FGM) and the middle zone of keratinized gingiva (MZ) between participants with an ISFP in the maxillary anterior region and participants with natural dentition and healthy gums; and 2) examine the perceptibility/acceptability of the differences in CIEDE2000 lightness, chroma and hue and in overall color, using the Euclidean and CIEDE2000 formulae.
Methods: The L*, a* and b* color coordinates were measured in 60 adult participants (30 with an ISFP and 30 with healthy teeth and gums) using a Spectroshade™ Micro spectrophotometer. From these coordinates, the changes in lightness (ΔL'), chroma (ΔC') and hue (ΔH') CIEDE2000 between the participants with and without an ISFP were quantified.
J Craniofac Surg
November 2024
Department of Oral and Maxillofacial Surgery, Dental Research Institute, School of Dentistry, Seoul National University, Seoul, Korea.
Background: Aesthetics is a crucial consideration in the anterior region, alongside dental implant survival and marginal bone loss (MBL). Bone-level implants are advantageous in the esthetic zone as they create a natural emergence profile with the use of customized abutments. This study aimed to assess the esthetic outcomes of internally submerged, tapered, bone-level dental implants and to evaluate associated alveolar bone changes.
View Article and Find Full Text PDFBMC Oral Health
January 2025
Department of Fixed Prosthodontics, Faculty of Dentistry, Cairo University, Cairo, Egypt.
Background: Anatomically formed healing abutments were suggested in literature to address many of the issues associated with immediate posterior implant insertion such as large extraction sockets that are extremely hard to seal without reflecting the mucoperiosteal flap, extraction sockets anatomy that are not suitable for regular healing abutment placement, and potentially high occlusal stresses when planning a temporary implant supported prothesis to improve the conditioning of supra implant tissue architecture and the emergence profile of the implant supported restorations.
Purpose: To clinically evaluate the peri-implant soft tissue profile of single posterior implant retained restorations and to assess patient related outcomes of the implant restorations that were conditioned immediately by CAD-CAM socket sealing abutments (SSA) versus those conditioned by Titanium (Ti) standard healing abutments (SHA).
Methods: Twenty participants received twenty-two single maxillary immediate implants after flapless minimally invasive tooth extraction and 3D guided implant placement in the posterior area (premolar and molar) and allocated randomly into two groups (n = 11), the intervention group: patients received PEEK SSA and the control group: the patients received Ti SHA.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!