A woman in her 80s experienced a life-threatening complication of pacemaker implant consisting of subacute right ventricular lead perforation causing iatrogenic injury to an intercostal artery, resulting in a large haemothorax. A CT scan confirmed active bleeding from the fourth intercostal artery. The patient underwent cardiothoracic surgery via a median sternotomy approach, during which the source of the bleeding was sealed, a new epicardial lead was positioned, and the original lead was extracted. This case emphasises the potentially severe consequences of pacemaker lead perforation and secondary injury to adjacent structures. It underscores the importance of early recognition and timely intervention, preferably in a tertiary specialist unit equipped for cardiothoracic surgery and confirms the value of pacemaker interrogation and CT scans for diagnosis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10860002PMC
http://dx.doi.org/10.1136/bcr-2023-258314DOI Listing

Publication Analysis

Top Keywords

lead perforation
12
intercostal artery
12
ventricular lead
8
iatrogenic injury
8
injury intercostal
8
pacemaker implant
8
cardiothoracic surgery
8
perforation iatrogenic
4
artery causing
4
causing haemothorax
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!