Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Cisplatin is a potent cytotoxic agent used in the treatment of various malignancies and exerts its antitumor effect through malignant cell DNA damage and apoptosis induction. Evaluation of systemic delivery of cisplatin is important in optimization of cisplatin treatment. However, accurate quantification of systemic cisplatin is challenging due to its various forms in circulation. This study aimed to develop a sensitive (LOQ < 0.1 µg/mL) and precise Ultra Performance Liquid Chromatography (UPLC) - Tandem Mass Spectrometry (MS/MS) method for quantifying free cisplatin in microdialysates and plasma. Furthermore the aim was to compare free cisplatin concentrations measured in standard plasma samples with those obtained from intravenous microdialysis catheters in a porcine model. The method developed utilizes dichloro(ethylenediamine)platinum(II) as an internal standard that co-elutes with cisplatin, ensuring precise correction for ion suppression/enhancement effects. The method was validated, demonstrating linearity up to 100 µg/mL and good intermediate precision (CV% < 6 %) in the range of 1.0-100 µg/mL, with an LOQ of 0.03 µg/mL. The pharmacokinetic parameters (AUC, C, T, and T) showed no significant differences between the two sampling methods. This validated LC-MS/MS method provides a reliable tool for quantifying systemic free cisplatin concentrations, facilitating future systemic and local pharmacokinetic evaluations for optimization of cisplatin-based cancer treatments.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jchromb.2024.124040 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!