In this study, overloaded elution profiles under ultra-high-pressure liquid chromatographic (UHPLC) conditions and accounting for the severe pressure and temperature gradients generated, are compared with experimental data. The model system consisted of an C18 column packed with 1.7-µm particles (i.e., a UHPLC column) and the solute was 1,3,5-tri‑tert-butylbenzene eluted with a mobile phase composed of 85/15 (v/v) acetonitrile/water. Two thermal modes were considered, and the solute was eluted at the very high inlet pressures necessary to achieve a highly efficient and rapid chromatographic process, as provided by using columns packed with small particles. However, the high inlet pressure and high linear velocity of the mobile phase caused the production of a significant amount of heat, and consequently, the formation of axial and radial temperature gradients. Due to these gradients, the retention and the mobile phase velocity were no longer constant. Thus, simple mathematical models consisting only of the mass balance equations are unsuitable to properly model the elution profiles. Here, the elution concentration profiles were predicted using a combined two-dimensional heat and mass transfer model, also including the calculation of the mobile phase velocity distribution. The isotherm adsorption model was the bi-Langmuir isotherm model with Henry constants that depended on the local temperature and pressure in the column. These adjustments allowed us to precisely account for changes in the shape and retention of the overloaded concentration profiles in the mobile phase. The proposed model provided accurate predictions of the overloaded concentration profiles, demonstrating good agreement with experimental profiles eluted under severe pressure and temperature gradients in the column even in the most extreme cases where the pressure drops reached 846 bar and the temperature gradients equaled 0.15 K mm and 0.95 K mm in the axial and the radial directions, respectively. In such cases 36 % decrease of the retention factor was observed along the column and 2 % increase in radial direction. These changes, combined with the velocity distribution, shifted the overloaded elution profile's shock towards the center of the column, advancing approximately 3 mm from its initial position close to the column wall. Ultimately, this resulted in the broadening of the elution band.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chroma.2024.464704 | DOI Listing |
Anal Chim Acta
March 2025
Van't Hoff Institute for Molecular Sciences (HIMS), University of Amsterdam, Science Park 904, 1098 XH, Amsterdam, the Netherlands; Centre for Analytical Sciences Amsterdam, Science Park 904, 1098 XH, Amsterdam, the Netherlands. Electronic address:
Background: Persistent and mobile organic compounds (PMOC) are of great concern for water quality and human health. The recent improvement and availability of high-resolution mass spectrometry in combination with liquid chromatography have widely expanded the potential of analytical workflows for their detection and quantitation in water. Given their high polarity, the detection of some PMOC requires alternative techniques to reversed-phase chromatography, such as hydrophilic interaction liquid chromatography (HILIC) and supercritical fluid chromatography (SFC).
View Article and Find Full Text PDFJ Chromatogr B Analyt Technol Biomed Life Sci
January 2025
University of Belgrade-Institute of Chemistry, Technology and Metallurgy, Department of Chemistry, Njegoševa 12, 11000 Belgrade, Republic of Serbia. Electronic address:
The lipophilicity of thirteen tacrine/piperidine-4-carboxamide derivatives was assessed using reversed-phase thin-layer chromatography (RP-TLC) with MeOH and acetonitrile (ACN) as organic modifiers. Among the parameters evaluated, the R and C values obtained using MeOH were identified as the most reliable for characterizing the lipophilicity of the investigated compounds. The observed differences in lipophilicity among the derivatives resulted from a delicate interplay of substituent effects (hydrophobicity, polarity, steric hindrance, and electronic effects), positional influence, and characteristics of the organic modifier.
View Article and Find Full Text PDFJMIR Res Protoc
January 2025
Data and Web Science Group, School of Business Informatics and Mathematics, University of Manneim, Mannheim, Germany.
Background: The rapid evolution of large language models (LLMs), such as Bidirectional Encoder Representations from Transformers (BERT; Google) and GPT (OpenAI), has introduced significant advancements in natural language processing. These models are increasingly integrated into various applications, including mental health support. However, the credibility of LLMs in providing reliable and explainable mental health information and support remains underexplored.
View Article and Find Full Text PDFPhys Rev Lett
December 2024
The Australian National University, Department of Quantum Science and Technology, Canberra, Australian Capital Territory 2601, Australia.
We demonstrate an atom interferometer measurement protocol compatible with operation on a dynamic platform. Our method employs two open interferometers, derived from the same atomic source, with different interrogation times to eliminate initial velocity dependence while retaining precision, accuracy, and long term stability. We validate the protocol by measuring gravitational tides, achieving a precision of 4.
View Article and Find Full Text PDFJ Sep Sci
January 2025
Chair of Environmental Chemistry and Bioanalytics, Faculty of Chemistry, Nicolaus Copernicus University in Toruń, Toruń, Poland.
Oligonucleotides (ONs) are an increasingly popular category of molecules in the pharmaceutical landscape, particularly attractive for the treatment of genetic and rare diseases. However, analyzing these molecules presents significant challenges, due to their highly hydrophilic nature, multiple negative charges, and the presence of closely related impurities resulting from the complex solid-phase synthesis process. Ion pairing reverse-phase liquid chromatography (IP-RPLC) is the preferred technique for ONs analysis but is not ideal for mass spectrometry (MS) coupling.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!