  • The 2023 Duke-ISCVID criteria for diagnosing infective endocarditis (IE) were tested against the previous 2000 Modified Duke and 2015 ESC criteria using a large patient cohort treated for the condition.
  • A total of 1194 patients were analyzed, revealing that the 2023 criteria had the highest sensitivity (97.6%) but the lowest specificity (46.0%) compared to the other criteria.
  • The lower specificity in the 2023 criteria was largely due to the inclusion of patients with cardiac implanted electronic devices (CIED), highlighting the need for cautious interpretation in this group.

Article Abstract

Background: The 2023 Duke-International Society for Cardiovascular Diseases (ISCVID) criteria for infective endocarditis (IE) were proposed as an updated diagnostic classification of IE. Using an open prospective multicenter cohort of patients treated for IE, we compared the performance of these new criteria to that of the 2000 Modified Duke and 2015 European Society of Cardiology (ESC) criteria.

Methods: Cases of patients treated for IE between January 2017 and October 2022 were adjudicated as certain IE or not. Each case was also categorized as either definite or possible/rejected within each classification. Sensitivity, specificity, and accuracy were estimated with 95% confidence intervals.

Results: Of the 1194 patients analyzed (mean age, 66.1 years; 71.2% males), 414 (34.7%) had a prosthetic valve and 284 (23.8%) had a cardiac implanted electronic device (CIED); 946 (79.2%) were adjudicated as certain IE; 978 (81.9%), 997 (83.5%), and 1057 (88.5%) were classified as definite IE in the 2000 modified Duke, 2015 ESC, and 2023 Duke-ISCVID criteria, respectively. The sensitivity of each set of criteria was 93.2% (95% confidence interval [CI], 91.6-94.8), 95.0% (95% CI, 93.7-96.4), and 97.6% (95% CI, 96.6-98.6), respectively (P < .001 for all 2-by-2 comparisons). Corresponding specificity rates were 61.3% (95% CI, 55.2-67.4), 60.5% (95% CI, 54.4-66.6), and 46.0% (95% CI, 39.8-52.2), respectively. In patients without CIED, sensitivity rates were 94.8% (95% CI, 93.2-96.4), 96.5% (95% CI, 95.1-97.8), and 97.7% (95% CI, 96.6-98.8); specificity rates were 59.0% (95% CI, 51.6-66.3), 56.6% (95% CI, 49.3-64.0), and 53.8% (95% CI, 46.3-61.2), respectively.

Conclusions: Overall, the 2023 Duke-ISCVID criteria had a significantly higher sensitivity but a significantly lower specificity compared with older criteria. This decreased specificity was mainly attributable to patients with CIED.

Download full-text PDF

Source
http://dx.doi.org/10.1093/cid/ciae035DOI Listing

Publication Analysis

Top Keywords

95%
13
2000 modified
12
modified duke
12
duke 2015
12
compared performance
8
2023 duke-international
8
duke-international society
8
society cardiovascular
8
2015 european
8
european society
8

Similar Publications

Article Synopsis
  • The study measured fibrinogen fluorescence at temperatures between 20 and 80 degrees Celsius across different pH levels.
  • It was found that raising the temperature from 20 to 40 degrees Celsius did not change the structure of fibrinogen in solutions with pH between 4.5 and 9.3.
  • However, temperatures between 40 to 50 degrees Celsius caused some structural changes in neutral solutions, and temperatures above 50-55 degrees Celsius led to significant denaturation of the fibrinogen molecule.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!