Content development for a new item-bank for measuring multifocal contact lens performance.

J Patient Rep Outcomes

Department of Optometry and Vision, Faculty of Optics and Optometry, Universidad Complutense de Madrid, Arcos de Jalón, 118, 28037, Madrid, Spain.

Published: February 2024

Background: Presbyopia is an age-related condition that causes a decreased ability to focus on nearby objects. Multifocal contact lenses are commonly used to address this issue. However, there seems to be a notable dissatisfaction among multifocal contact lens wearers. The absence of a reliable instrument to measure the patient's perspective, despite the widespread use of this method, highlights the need for further research in this area.

Objective: The objective of this study is to develop an item-bank integrating all domains necessary to assess the patient's perspective on multifocal contact lens performance, offering a comprehensive measure. The item-bank will ensure a high level of content validity, be self-administered, and will initially be available in Spanish. The aim of this tool is to serve as a valuable resource for research and optometric clinics, facilitating the follow-up of patients with presbyopia who wear multifocal contact lenses or those who are newly starting to use them.

Methodology: The MCL-PRO item bank, followed a systematic and step-wise inductive approach to gather information, following the recommendations outlined in the COSMIN guidelines and similar studies. The process involved the following steps: (1) Literature review and relevant existing items identification (2) Social media review, (3) Semi-structured focus groups, (4) performing qualitative analysis, (5) refining and revising the items, and (6) generating the content of the item bank.

Results: A total of 575 items were included in the item-bank hosted under 8 different domains that were found to be important for presbyopic population: visual symptoms (213), activity limitation (111), ocular symptoms (135), convenience (36), emotional well-being (33), general symptoms (16), cognitive issues (21) and economic issues (10).

Conclusion: The item-bank created has followed standardised methodology for its development and encloses all the aspects for MCL performance evaluation from patients perspective.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10853121PMC
http://dx.doi.org/10.1186/s41687-024-00689-wDOI Listing

Publication Analysis

Top Keywords

multifocal contact
20
contact lens
12
lens performance
8
contact lenses
8
patient's perspective
8
item-bank
5
multifocal
5
contact
5
content development
4
development item-bank
4

Similar Publications

A lensless compact arrangement based on digital in-line holography under Gabor's regime is proposed as a novel contactless method to assess the profile of multifocal intraocular lenses (MIOLs) which are conformed by several diffractive rings. Diffractive MIOLs are a widely adopted ophthalmologic option for the correction of presbyopia in patients undergoing cataract surgery. The MIOL optical design might introduce non-negligible optical performance differences between lenses as well as the introduction of undesirable photic phenomena (such as halos and glare) affecting the vision of users.

View Article and Find Full Text PDF

Introduction: Annual screening for hydroxychloroquine (HCQ) retinopathy is recommended, and electroretinography (ERG) is considered a gold-standard test, but there are screening shortfalls and standard ERG is burdensome and has limited availability. Newer, portable ERG devices using skin-based electrodes may increase screening capacity but need validation. This study aims to determine initial device accuracies and feasibility of further research.

View Article and Find Full Text PDF

This study investigates whether a diffractive presbyopia-correcting multifocal intraocular lens disrupts the favorable interaction between chromatic and monochromatic aberrations in the eye. This is analyzed not only for distant objects but also for closer viewing distances, where the lens utilizes different diffraction orders depending on its design. We consider diffractive designs based on the zero-diffraction order for far vision and the first diffraction order for near vision (i.

View Article and Find Full Text PDF

Purpose: Numerous multifocal soft contact lenses have been introduced into clinical practice over the past half century. The purpose of this work is to update earlier surveys by describing international trends in multifocal and monovision soft lens fitting for presbyopia between 2000-2023, inclusive.

Method: An annual contact lens prescribing survey was sent to eye care practitioners in up to 71 countries between 2000-2023.

View Article and Find Full Text PDF

Trial Design: Double-masked crossover RCT (Research Registry: #8136) comparison of a new HOYA one-day disposable multifocal contact lens (HOMCL) with Alcon DAILIES TOTAL1® Multifocal (ADT1).

Methods: Sixty presbyopic participants from three countries attended for baseline measurements and fitting of both lens types and then for a fortnight completed daily diaries of symptoms with habitual optical correction, and VF-14 questionnaire. Participants collected either HOMCL or ADT1, when the vision was measured again, and they wore this product for a fortnight, completing daily diaries and VF-14.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!