Purpose: To detect the viral RNA load of SARS-CoV-2 in conjunctival swabs of COVID-19 patients, and compare with nasopharyngeal swabs.

Methods: Conjunctival swabs of COVID-19 patients (with PCR positive nasopharyngeal swabs) were subjected to quantitative reverse transcription-polymerase chain reaction (RT-PCR) for detection of SARS-CoV-2 RNA. The cycle threshold (Ct) values of Open Reading Frame 1 (ORF 1 Ab gene) and nucleoprotein (N gene) PCRs were used to assess the viral RNA load, and compare them with the baseline values of nasopharyngeal swabs.

Results: Of 93 patients, 17 (18.27%) demonstrated SARS-CoV-2 RNA in conjunctival swabs. Baseline nasopharyngeal swabs were collected at a median of 2 days; while, the conjunctival swabs were collected at median 7 days, from onset of illness (p < 0.001). Despite a significant delay in conjunctival swab collection than nasopharyngeal swabs, the Ct values (ORF or N gene PCRs) were comparable between nasopharyngeal swab and conjunctival swab samples. Subsequently, during the recovery period, in four of these 17 patients (with conjunctival swab positivity), when the second nasopharyngeal swab was 'negative', the conjunctival swab was 'positive'.

Conclusion: The conjunctival swabs demonstrated SARS-CoV-2 RNA in 17 (18.27%) of 93 COVID-19 patients. Our results may suggest a delayed or a prolonged shedding of the virus/viral RNA on the ocular surface than in nasopharyngeal mucosa.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10792-024-02976-3DOI Listing

Publication Analysis

Top Keywords

conjunctival swabs
20
sars-cov-2 rna
12
cycle threshold
8
threshold values
8
rna conjunctival
8
viral rna
8
rna load
8
swabs covid-19
8
covid-19 patients
8
nasopharyngeal swabs
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!