We aimed to develop a large animal model of subcoronary aortic stenosis (AS) to study intracoronary and microcirculatory hemodynamics. A total of three surgical techniques inducing AS were evaluated in 12 sheep. Suturing the leaflets together around a dilator ( = 2) did not result in severe AS. Suturing of a pericardial patch with a variable opening just below the aortic valve ( = 5) created an AS which was poorly tolerated if the aortic valve area (AVA) was too small (0.38-1.02 cm), but was feasible with an AVA of 1.2 cm. However, standardization of aortic regurgitation (AR) with this technique is difficult. Therefore, we opted for implantation of an undersized AV-bioprosthesis with narrowing sutures on the leaflets ( = 5). Overall, five sheep survived the immediate postoperative period of which three had severe AS (one patch and two bioprostheses). The surviving sheep with severe AS developed left ventricular hypertrophy and signs of increased filling-pressures. Intracoronary assessment of physiological indices in these AS sheep pointed toward the development of functional microvascular dysfunction, with a significant increase in coronary resting flow and hyperemic coronary resistance, resulting in a significantly higher index of microvascular resistance (IMR) and lower myocardial resistance reserve (MRR). Microscopic analysis showed myocardial hypertrophy and signs of fibrosis without evidence of capillary rarefaction. In a large animal model of AS, microvascular changes are characterized by increased resting coronary flow and hyperemic coronary resistance resulting in increased IMR and decreased MRR. These physiological changes can influence the interpretation of regularly used coronary indices. In an animal model of aortic valve stenosis (AS), coronary physiological changes are characterized by increased resting coronary flow and hyperemic coronary resistance. These changes can impact coronary indices frequently used to assess concomitant coronary artery disease (CAD). At this point, the best way to assess and treat CAD in AS remains unclear. Our data suggest that fractional flow reserve may underestimate CAD, and nonhyperemic pressure ratios may overestimate CAD severity before aortic valve replacement.

Download full-text PDF

Source
http://dx.doi.org/10.1152/japplphysiol.00737.2023DOI Listing

Publication Analysis

Top Keywords

aortic valve
20
animal model
12
flow hyperemic
12
hyperemic coronary
12
coronary resistance
12
coronary
11
valve stenosis
8
large animal
8
hypertrophy signs
8
changes characterized
8

Similar Publications

Background: Despite advancements in valve implantation devices, vascular access complications (VAC) remain a significant cause of morbidity and mortality for those undergoing transcatheter aortic valve replacement (TAVR). We describe pre-operative imaging analysis of the aortoiliac and femoral arterial beds using the TransAtlantic intersociety consensus (TASC) score, ilio-femoral tortuosity, and procedural characteristics to identify anatomic risk factors predictive of VAC in TAVR.

Methods: Consecutive patients undergoing TAVR from 2012 to 2022 at a single North Dakota hospital were retrospectively reviewed.

View Article and Find Full Text PDF

Background: Transcatheter aortic valve replacement (TAVR) is a well-established treatment option for patients with severe aortic valve stenosis; however, clinical valve thrombosis is a major challenge.

Case Summary: A 92-year-old woman underwent TAVR for severe aortic stenosis. One month later, the patient developed acute heart failure.

View Article and Find Full Text PDF

We report a 75-year-old female with a history of two heart operations: aortic valve replacement (St. Jude Medical 21 mm) at the age of 44 years for severe rheumatic aortic stenosis and mitral valve replacement (Carbomedics 29 mm) at the age of 51 years for rheumatic mitral regurgitation. Decades later, she presented with exertional dyspnea.

View Article and Find Full Text PDF

Introduction The study aimed to retrospectively evaluate the early patient outcome and left ventricular function after mitral valve replacement with a tilting disc valve and total preservation. Patients and methods This retrospective observational study includes patients who underwent mitral valve replacement using a tilting disc valve with total preservation of mitral valvular and subvalvular apparatus from July 2021 to August 2022 at a single center. Results The data were reviewed retrospectively for age, sex, comorbidities, operating time, aortic cross-clamp time, cardiopulmonary bypass time, preoperative and postoperative left ventricular ejection fraction, mean gradient across the mitral valve, left ventricular diameter, left atrial size, atrial fibrillation, complications, mortality, and early patient outcome.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!