Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The rapid delayed rectifier potassium current (I) is important for cardiac repolarization and is most often involved in drug-induced arrhythmias. However, accurately measuring this current can be challenging in human-induced pluripotent stem cell (hiPSC)-derived cardiomyocytes because of its small current density. Interestingly, the ion channel conducting I, hERG channel, is not only permeable to K ions but also to Cs ions when present in equimolar concentrations inside and outside of the cell. In this study, I was measured from Chinese hamster ovary (CHO)-hERG cells and hiPSC-CM using either Cs or K as the charge carrier. Equimolar Cs has been used in the literature in manual patch-clamp experiments, and here, we apply this approach using automated patch-clamp systems. Four different (pre)clinical drugs were tested to compare their effects on Cs- and K-based currents. Using equimolar Cs solutions gave rise to approximately ten-fold larger hERG conductances. Comparison of Cs- and K-mediated currents upon application of dofetilide, desipramine, moxifloxacin, or LUF7244 revealed many similarities in inhibition or activation properties of the drugs studied. Using equimolar Cs solutions gave rise to approximately ten-fold larger hERG conductances. In hiPSC-CM, the Cs-based conductance is larger compared to the known K-based conductance, and the Cs hERG conductance can be inhibited similarly to the K-based conductance. Using equimolar Cs instead of K for I measurements in an automated patch-clamp system gives rise to a new method by which, for example, quick scans can be performed on effects of drugs on hERG currents. This application is specifically relevant when such experiments are performed using cells which express small I current densities in combination with small membrane capacitances.