Background: Computed tomography (CT) image integration is of limited use in left ventricular (LV) ablation due to inadequate accuracy of registration. The current study aimed to investigate the accuracy and feasibility of extra-cavity LV image registration via the coronary cusp.

Methods: Consecutive patients were enrolled as the validation group (n = 41) and feasibility group (n = 48). After extra-cavity registration via the aortic root, the LV anatomy derived from CT image was activated and moved into real space. Accuracy of LV anatomy via this registration method was verified by intracardiac echocardiography reconstruction in the validation group and tested further in the feasibility group via measuring the location differences (<3 mm) and volume difference (<8 mL).

Results: In validation group, the LV volume of CT image and ICE map were comparable (113.6 ± 15.5 mL vs. 109.0 ± 15.3 mL, P =.27), and the location difference was 3.1 ± 1.1 mm at LV summit, 1.8 ± 0.9 mm at the free wall, and 1.8 ± 0.7 mm at the LV apex. There was a mean of 2.9 ± 1.2 mm and 3.0 ± 1.0 mm length difference in anterior PM and posterior PM, the position difference of the PM's base was 2.8 ± 0.9 mm for anterior PM and 2.2 ± 0.9 mm for posterior PM. In feasibility group, the distance differences of LV summit, LV septum, LV apex, and LV free averaged 1.8 ± 0.8 mm, 1.5 ± 0.7 mm, 1.4 ± 0.6 mm, 1.3 ± 0.7 mm, respectively. Compared with validation group, acute success (100% vs. 96.5%, P =.51), complications rate (4.9% vs. 2.0%, P = 0.59) and fluoroscopic time (1.6 ± 1.1 vs. 1.9 ± 1.6 minutes, P =.30) exhibited no significant difference, but was significantly reduced with procedure time (74.5 ± 8.1 vs. 61.2 ± 9.5 minutes, P <.001) with CT image registration only.

Conclusion: LV mapping and ablation could be successfully achieved by extra-cavity registration via coronary cusp without needing positions within LV beforehand.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11017683PMC
http://dx.doi.org/10.14744/AnatolJCardiol.2023.3264DOI Listing

Publication Analysis

Top Keywords

extra-cavity image
8
image registration
8
registration aortic
8
aortic root
8
left ventricular
8
validation group
8
feasibility group
8
registration
5
root left
4
ventricular mapping
4

Similar Publications

Telemedicine Interventional Therapy, Extra-cavity LV Image Registration….

Anatol J Cardiol

April 2024

Department of Cardiology, Ankara University Faculty of Medicine, İbn-i Sina Hospital, Ankara, Türkiye.

View Article and Find Full Text PDF

Background: Computed tomography (CT) image integration is of limited use in left ventricular (LV) ablation due to inadequate accuracy of registration. The current study aimed to investigate the accuracy and feasibility of extra-cavity LV image registration via the coronary cusp.

Methods: Consecutive patients were enrolled as the validation group (n = 41) and feasibility group (n = 48).

View Article and Find Full Text PDF

Stretched-pulse mode-locked (SPML) lasing based on a chirped fiber Bragg grating (CFBG) has proven to be a powerful method to generate wavelength-swept lasers at speeds of tens of megahertz. However, light transmitted through the CFBG may lead to undesirable laser oscillation that disrupts the mechanism of the laser active mode locking in the theta ring cavity. In this Letter, we demonstrate a simple and low-cost approach to suppress the transmitted light and achieve an effective duty cycle of ∼100% with only one CFBG and no need for intra-cavity semiconductor optical amplifier (SOA) modulation, extra-cavity optical buffering, and post amplification.

View Article and Find Full Text PDF

We demonstrate a flat broadband time-stretched swept source based on extra-cavity spectral shaping. By adjusting the polarization-dependent gain profile and driving current of the booster optical amplifier (BOA), extra-cavity spectral shaping is optimized to generate output with a 1-dB bandwidth of ∼100 nm, 3-dB bandwidth of ∼140 nm and output power of ∼21.4 mW.

View Article and Find Full Text PDF

Spatial Coherence Manipulation on the Disorder-Engineered Statistical Photonic Platform.

Nano Lett

August 2022

The Key Laboratory of Weak Light Nonlinear Photonics, Ministry of Education, Renewable Energy Conversion and Storage Center, School of Physics and TEDA Institute of Applied Physics, Nankai University, Tianjin 300071, China.

Coherence, similar to amplitude, polarization, and phase, is a fundamental characteristic of the light fields and is dominated by the statistical optical property. Although spatial coherence is one of the pivotal optical dimensions, it has not been significantly manipulated on the photonic platform. Here, we theoretically and experimentally manipulate the spatial coherence of light fields by loading different random phase distributions onto the wavefront with a metasurface.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!