Diagnosing coronary microvascular dysfunction remains challenging, primarily due to the lack of direct measurements of absolute coronary blood flow (Q) and microvascular resistance (R). However, there has been recent progress with the development and validation of continuous intracoronary thermodilution, which offers a simplified and validated approach for clinical use. This technique enables direct quantification of Q and R, leading to precise and accurate evaluation of the coronary microcirculation. To ensure consistent and reliable results, it is crucial to follow a standardized protocol when performing continuous intracoronary thermodilution measurements. This document aims to summarize the principles of thermodilution-derived absolute coronary flow measurements and propose a standardized method for conducting these assessments. The proposed standardization serves as a guide to ensure the best practice of the method, enhancing the clinical assessment of the coronary microcirculation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jacc.2023.12.014DOI Listing

Publication Analysis

Top Keywords

absolute coronary
12
coronary flow
8
continuous intracoronary
8
intracoronary thermodilution
8
coronary microcirculation
8
coronary
6
measuring absolute
4
flow and microvascular
4
and microvascular resistance
4
resistance by thermodilution
4

Similar Publications

This study aimed to evaluate the causal effects of different immune cells on heart failure (HF) using Mendelian randomization (MR). Datasets for immune cell phenotypes and HF were obtained from European Bioinformatics Institute and FinnGen. Then, single nucleotide polymorphisms were screened according to the basic assumptions of MR.

View Article and Find Full Text PDF

Background: The prevalence of very high-risk atherosclerotic cardiovascular disease (ASCVD) is significant in China, with suboptimal rates of low-density lipoprotein cholesterol (LDL-C) compliance exacerbating plaque instability and causing a higher incidence of major adverse cardiac events (MACEs). Proprotein convertase subtilisin/kexin type 9 inhibitors (PCSK9i) are effective in reducing LDL-C levels, increase the stability of vulnerable plaque, and influence the progression of atherosclerosis through multiple mechanisms as demonstrated in animal studies. However, there is currently a lack of evidence regarding the efficacy and safety of high-intensity statin therapy combined with PCSK9i in the secondary prevention of ASCVD in the Chinese population.

View Article and Find Full Text PDF

Value of Myocardial Strain in Monitoring Fluorouracil-Based Chemotherapy-Related Cardiac Dysfunction in Gastrointestinal Cancer Patients.

Chin Med Sci J

November 2024

State Key Laboratory for Innovation and Transformation of Luobing Theory; Key Laboratory of Cardiovascular Remodeling and Function Research, Chinese Ministry of Education, Chinese National Health Commission and Chinese Academy of Medical Sciences; Department of Cardiology, Qilu Hospital of Shandong University, Jinan 250012, China.

Objectives: To investigate the predictive value of myocardial strain for cardiotoxicity associated with fluorouracil-based chemotherapies in gastrointestinal cancer patients.

Methods: Patients with diagnosis of gastrointestinal cancers, who were hospitalized for chemotherapy involving antimetabolic drugs, were eligible in this prospective study. Echocardiography was performed before and after each chemotherapy cycle during hospitalization until the completion of chemotherapy.

View Article and Find Full Text PDF

Reliability and Accuracy of the Fitbit Charge 4 Photoplethysmography Heart Rate Sensor in Ecological Conditions: Validation Study.

JMIR Mhealth Uhealth

January 2025

ULR 7369 - URePSSS - Unité de Recherche Pluridisciplinaire Sport Santé Société, Univ. Littoral Côte d'Opale, Univ. Lille, Univ. Artois, 189b, Avenue Maurice Schumann, Centre Universitaire des Darses, Dunkerque, 59375, France, 33 328237357.

Background: Wrist-worn photoplethysmography (PPG) sensors allow for continuous heart rate (HR) measurement without the inconveniences of wearing a chest belt. Although green light PPG technology reduces HR measurement motion artifacts, only a limited number of studies have investigated the reliability and accuracy of wearables in non-laboratory-controlled conditions with actual specific and various physical activity movements.

Objective: The purpose of this study was to (1) assess the reliability and accuracy of the PPG-based HR sensor of the Fitbit Charge 4 (FC4) in ecological conditions and (2) quantify the potential variability caused by the nature of activities.

View Article and Find Full Text PDF

Background: Pulse pressure variation (PPV) is limited in low tidal volume mechanical ventilation. We conducted this systematic review and meta-analysis to evaluate whether passive leg raising (PLR)-induced changes in PPV can reliably predict preload/fluid responsiveness in mechanically ventilated patients with low tidal volume in the intensive care unit.

Methods: PubMed, Embase, and Cochrane databases were screened for diagnostic research relevant to the predictability of PPV change after PLR in low-tidal volume mechanically ventilated patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!