Purpose: To compare the corneal biomechanical parameters in healthy corneas with symmetric and asymmetric bow-tie topographic patterns.
Methods: In this cross-sectional study, 144 eyes were divided based on inferior-superior asymmetry value (I-S) into symmetric (zero I-S: - 0.50 to + 0.50 D) and asymmetric bow-tie topographic patterns with inferior (positive I-S: + 0.51 to + 1.4 D) or superior (negative I-S: - 2.5 to - 0.51 D) steepening. The biomechanical assessment was performed using Corvis ST and ocular response analyzer (ORA). A general linear model univariate analysis was used to compare the parameters, while the central corneal thickness, intraocular pressure, and age were considered covariates.
Results: Only the peak distance (PD) at the highest concavity phase (P = 0.007) and tomographic biomechanical index (TBI, P = 0.001) showed statistically significant differences between the three groups. For TBI, this difference was statistically significant between the positive I-S group separately with the zero I-S group (P < 0.001), and with the negative I-S group (P = 0.022). For PD, the significant difference was between the negative I-S group separately with zero I-S (P = 0.019), and positive I-S groups (P = 0.018). There was a statistically significant correlation between the I-S value with PD (r = 0.281, P = 0.001) and TBI (r = 0.170, P = 0.044).
Conclusions: Most corneal biomechanical parameters are not statistically significant compared to the zero I-S group. However, superior steepening is associated with a stiffer response based solely on the shorter PD values seen in this group, and the group with the inferior steepening shows the highest or more suspicious values based on TBI.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10792-024-02921-4 | DOI Listing |
Invest Ophthalmol Vis Sci
August 2024
Ophthalmology Clinic, Department of Medicine and Aging Sciences, University "G. D'Annunzio" of Chieti-Pescara, Chieti, Italy.
Purpose: The purpose of this study was to explore the optimal shape of customized lenticules for stromal lenticule addition keratoplasty (SLAK) for off-centered ectasia.
Methods: Two different methods to create ex vivo models of eccentric-keratoconus were investigated. Twelve human corneas were used to create model 1 by a hyperopic photorefractive keratectomy (PRK), and model 2 by masked phototherapeutic keratectomy (PTK) on the anterior corneal surface, whereas both types received myopic ablation of the posterior surface.
Sci Rep
April 2024
Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, 251 Fukang Road, Tianjin, 300000, China.
A retrospective cohort study was conducted to observe the correction effect of Toric intraocular lens (IOL) implantation in cataract eyes with specific types of irregular corneal astigmatism. Thirty-four eyes with either the "asymmetric bow-tie" pattern (Type I) or the "angled bow-tie" pattern (Type II) were included. Corneal topography was assessed using Pentacam HR, and changes in preoperative corneal astigmatism, visual acuity, manifest refraction, and objective visual quality were measured and compared.
View Article and Find Full Text PDFInt Ophthalmol
February 2024
Student Research Committee, Rehabilitation Sciences Research Center, Zahedan University of Medical Sciences, Zahedan, Iran.
Purpose: To compare the corneal biomechanical parameters in healthy corneas with symmetric and asymmetric bow-tie topographic patterns.
Methods: In this cross-sectional study, 144 eyes were divided based on inferior-superior asymmetry value (I-S) into symmetric (zero I-S: - 0.50 to + 0.
Nanotechnology
January 2024
Univ. of Bucharest, Physics Faculty, PO Box MG-11, 077125 Bucharest, Romania.
In this paper, we demonstrate experimentally that field-effect transistors with nanoconstricted graphene monolayer channels have a subthreshold swing (SS) below 60 mV/dec, which is slightly dependent on temperature. Two shapes of nanoconstricted graphene monolayers are considered: (i) a bow-tie shape, representative for a symmetric channel, and (ii) a trapezoidal shape, which illustrates an asymmetric channel. While both types of nonuniform channels are opening a bandgap in graphene, thus showing an on/off ratio of 10, the SS in the graphene bow-tie channel is below 60 mV/dec in the temperature range 25 °C-44 °C.
View Article and Find Full Text PDFCornea
May 2024
Department of Ophthalmology, University of Helsinki and Helsinki University Hospital, Helsinki, Finland.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!