A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Coherent Modulation of the Aggregation Behavior and Intramolecular Charge Transfer in Small Molecule Probes for Sensitive and Long-term Nerve Agent Monitoring. | LitMetric

Aggregation-induced emission (AIE) shows promising performance in chemical sensing relying on the change of the emission behavior of the probe molecule monomers to the aggregated product. However, whether the response contrast could be further boosted by utilizing the emission property of the aggregated probe and the aggregated product remains a big challenge. Here, an exciting AIE probe regulation strategy was proposed by coherently modulating the aggregation behavior and the intramolecular charge transfer (ICT) property of the probes and thus an aggregated-to-aggregated colorimetric-fluorescent dual-mode detection was achieved. The blue emissive film obtained with the optimal AIE probe has been proven to be effective to recognize the vapor of nerve agent analog DCP in air by emitting a sharp green fluorescence. In addition, a porous polymer-based wet sensing chip loaded with the probe enables the immediate response to DCP vapor with a limit of detection (LOD) of 1.7 ppb, and it was further integrated into a wearable watch device for long-term monitoring of DCP vapor up to two weeks. We expect the present probe design strategy would greatly deepen the AIE-based science and provide new insights for long-term monitoring sensors toward trace hazardous substances.

Download full-text PDF

Source
http://dx.doi.org/10.1002/anie.202400453DOI Listing

Publication Analysis

Top Keywords

aggregation behavior
8
behavior intramolecular
8
intramolecular charge
8
charge transfer
8
nerve agent
8
aggregated product
8
aie probe
8
dcp vapor
8
long-term monitoring
8
probe
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!