This study aims to evaluate the practicality of handheld digital X-ray in determining the position of the electrode array following Cochlear implantation (CI). A retrospective study was conducted involving 11 patients (12 ears) who underwent intraoperative imaging via handheld X-ray (MINE ALNU®, OTOM, Gwangju, South Korea) post-CI between December 2021 and January 2023. Immediate confirmation of the correct electrode array placement in the cochlea was achieved, with subsequent comparisons made to C-arm image and postoperative transorbital view X-ray. Rapid intraoperative imaging was achieved in all instances. The electrode types used included 9 Nucleus slim modiolar electrodes, 1 Nucleus contour electrode, and 2 Medel flex26 electrodes. A malpositioned electrode array was detected in one patient. The handheld digital X-ray also adeptly visualized the electrodes implanted in pediatric patients. The use of intraoperative handheld digital X-ray using MINE ALNU® proves to be a safe, efficient, straightforward, and reliable method for immediate identification of an inserted electrode array. It has potential to replace the traditional C-arm X-ray for verifying electrode positioning in the operating room.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/01455613231223954 | DOI Listing |
Oral Radiol
January 2025
Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Av. Limeira, 901, Areião, Piracicaba, SP, 13414-903, Brazil.
Objectives: To assess the influence of a handheld X-ray unit in the diagnosis of proximal caries lesions using different digital systems by comparing with a wall-mounted unit.
Methods: Radiographs of 40 human teeth were acquired using the Eagle X-ray handheld unit (Alliage, São Paulo, Brazil) set at 2.5 mA, 60 kVp and an exposure time of 0.
J Orthop Surg Res
January 2025
Program of Physical Therapy, Department of Medical Rehabilitation Sciences, College of Applied Medical Sciences, King Khalid University, Abha, Saudi Arabia.
Background: Ankle joint position sense (AJPS) accuracy and postural control are crucial for maintaining balance and stability, particularly in individuals with plantar fasciitis who may experience proprioceptive and functional impairments. Understanding how psychosocial factors, such as pain catastrophizing, and biomechanical measures, like muscle strength and gait parameters related to proprioception and postural control, can inform more effective treatment approaches. This study aimed to (1) examine the relationship between AJPS accuracy and biomechanical factors-including postural stability, lower limb muscle strength, and gait parameters-in individuals with plantar fasciitis d (2) analyze the impact of psychosocial factors, including pain catastrophizing, physical activity level, and quality of life, on AJPS accuracy and postural control in this population.
View Article and Find Full Text PDFAnn Ital Chir
January 2025
Department of Thoracic Surgery, Mindong Hospital Affiliated to Fujian Medical University, 355000 Fu'an, Fujian China.
Aim: This study aimed to explore the efficacy of open reduction and internal fixation assisted by handheld ultrasound combined with three-dimensional (3D) printing technology in treating multiple rib fractures.
Methods: We retrospectively analyzed the clinical data from 84 patients affected with multiple rib fractures admitted to our hospital between August 2022 and April 2024. After excluding four cases, 80 cases were included in this study.
JMIR Form Res
January 2025
Limburg Clinical Research Center/Mobile Health Unit, Faculty of Medicine and Life Sciences, Hasselt University, Hasselt, Belgium.
Background: Consumer-oriented wearable devices (CWDs) such as smartphones and smartwatches have gained prominence for their ability to detect atrial fibrillation (AF) through proprietary algorithms using electrocardiography or photoplethysmography (PPG)-based digital recordings. Despite numerous individual validation studies, a direct comparison of interdevice performance is lacking.
Objective: This study aimed to evaluate and compare the ability of CWDs to distinguish between sinus rhythm and AF.
PLoS One
January 2025
Department of Sport, Exercise and Rehabilitation, Northumbria University, Newcastle upon Tyne, United Kingdom.
Ocular microtremor (OMT) is a fixational eye movement that cannot be seen with the naked eye but is always present, even when the eye appears motionless/still. The link between OMT and brain function provides a strong rationale for investigation as there lies potential for its use as a biomarker in populations with neurological impairments. OMT frequency is typically 70-80Hz in healthy adults and research suggests that this will be reduced in those with neurological disease such as Parkinson's Disease (PD).