Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Coherent light detection and ranging (LiDAR), particularly the frequency-modulated continuous-wave LiDAR, is a robust optical imaging technology for measuring long-range distance and velocity in three dimensions (3D). We propose a spatio-spectral coherent LiDAR based on a unique wavelength-swept laser to enable both axial coherent ranging and lateral spatio-spectral beam scanning simultaneously. Instead of the conventional unidirectional wavelength-swept laser, a flutter-wavelength-swept laser (FWSL) successfully decoupled bidirectional wavelength modulation and continuous wavelength sweep, which overcame the measurable distance limited by the sampling process. The decoupled operation in FWSL enabled sequential sampling of flutter-wavelength modulation across its wide spectral bandwidth of 160 nm and, thus, allowed simultaneous distance and velocity measurement over an extended measurable distance. Herein, complete four-dimensional (4D) imaging, combining real-time 3D distance and velocity measurements, was implemented by solid-state beam scanning. An acousto-optic scanner was synchronized to facilitate the other lateral beam scanning, resulting in an optimized solid-state coherent LiDAR system. The proposed spatio-spectral coherent LiDAR system achieved high-resolution coherent ranging over long distances and real-time 4D imaging with a frame rate of 10 Hz, even in challenging environments.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10847489 | PMC |
http://dx.doi.org/10.1038/s41467-024-45297-w | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!