A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[HVPG minimally invasive era: exploration based on forearm venous approach]. | LitMetric

The transjugular or transfemoral approach is used as a common method for hepatic venous pressure gradient (HVPG) measurement in current practice. This study aims to confirm the safety and effectiveness of measuring HVPG via the forearm venous approach. Prospective recruitment was conducted for patients with cirrhosis who underwent HVPG measurement via the forearm venous approach at six hospitals in China and Japan from September 2020 to December 2020. Patients' clinical baseline information and HVPG measurement data were collected. The right median cubital vein or basilic vein approach for all enrolled patients was selected. The HVPG standard process was used to measure pressure. Research data were analyzed using SPSS 22.0 statistical software. Quantitative data were used to represent medians (interquartile ranges), while qualitative data were used to represent frequency and rates. The correlation between two sets of data was analyzed using Pearson correlation analysis. A total of 43 cases were enrolled in this study. Of these, 41 (95.3%) successfully underwent HVPG measurement via the forearm venous approach. None of the patients had any serious complications. The median operation time for HVPG detection via forearm vein was 18.0 minutes (12.3~38.8 minutes). This study confirmed that HVPG was positively closely related to Child-Pugh score ( = 0.47, = 0.002), albumin-bilirubin score ( = 0.37, = 0.001), Lok index ( = 0.36, = 0.02), liver stiffness ( = 0.58, = 0.01), and spleen stiffness ( = 0.77, = 0.01), while negatively correlated with albumin ( = -0.42, = 0.006). The results of this multi-centre retrospective study suggest that HVPG measurement via the forearm venous approach is safe and feasible.

Download full-text PDF

Source
http://dx.doi.org/10.3760/cma.j.cn501113-20231220-00289DOI Listing

Publication Analysis

Top Keywords

forearm venous
20
hvpg measurement
20
venous approach
16
measurement forearm
12
hvpg
9
underwent hvpg
8
data analyzed
8
data represent
8
forearm
6
venous
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!