Bundle branch re-entry after transcatheter aortic valve replacement.

Indian Pacing Electrophysiol J

Advocate Sherman Hospital, 1435 Randall Road Suite 206, Elgin, IL, 60123, USA. Electronic address:

Published: February 2024

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11143717PMC
http://dx.doi.org/10.1016/j.ipej.2024.01.009DOI Listing

Publication Analysis

Top Keywords

bundle branch
4
branch re-entry
4
re-entry transcatheter
4
transcatheter aortic
4
aortic valve
4
valve replacement
4
bundle
1
re-entry
1
transcatheter
1
aortic
1

Similar Publications

Background: Right ventricular (RV) function assessment by echocardiography can be challenging due to its complex morphology. Also, increasing use of sedation rather than general anesthesia for transfemoral approach transcatheter aortic valve replacement (TAVR) reduces the need for intraoperative transesophageal echocardiography (TEE). Recent clinical studies have demonstrated the importance of 3-dimensional (3D) echocardiography and a longitudinal strain for RV function assessment.

View Article and Find Full Text PDF

The Spatial Ventricular Gradient Is Associated with Pacing-Induced Cardiomyopathy.

Heart Rhythm

December 2024

Harvard-Thorndike Electrophysiology Institute, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA. Electronic address:

Background: Pacing-induced cardiomyopathy (PICM) is a frequent complication of right ventricular pacing that often requires re-operation for biventricular or conduction system pacing. Better methods for predicting PICM may inform initial pacing strategy and follow-up monitoring.

Objective: To determine if the spatial ventricular gradient (SVG), a vectorcardiographic marker of ventricular electrical and mechanical heterogeneity, is associated with subsequent development of PICM.

View Article and Find Full Text PDF

Background Ventricular septal pacing has long been performed using a stylet during pacemaker implantation, but with the availability of guiding catheters, His bundle pacing and left bundle branch area pacing have also been performed. However, it is not known to what extent the tip load of the ventricular lead differs when a guiding catheter is used compared with a stylet alone. In this study, the tip load was measured for different stylet stiffness and guiding catheter geometries at sites where His bundle pacing and left bundle branch area pacing were assumed.

View Article and Find Full Text PDF

Background: Interventricular dyssynchrony derived from the classic non-physiological stimulation (n-PS) of the right ventricle (RV) is a known cause of left ventricular dysfunction (LVDys).

Methods: This was a prospective descriptive single-center study. We analyzed patients who develop LVDys with n-PS, and the results after upgrading to conduction system pacing (CSP).

View Article and Find Full Text PDF

Background: Coronary Artery Spasm (CAS) often presents in the epicardial coronary arteries. The anterior septal branch is distributed within the myocardium, and occurrences of spasms are rare. Currently, there is no available literature on this topic, and the onset of symptoms remains elusive, potentially leading to misdiagnosis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!