Recombinant human erythropoietin (rhEPO) has been abused as a performance enhancer in sports for several years, but with advancements in detection methods, even micro-doses can be detected in dried blood spot (DBS) samples. Here, we present the results from an Eporatio® (epoetin theta) micro-dose administration study to detect rhEPO in DBS samples. Five healthy male volunteers received a 15 IU/kg subcutaneous dose of Eporatio®. Urine and DBS samples (Mitra® VAMS and Capitainer® B50) were collected 1, 10, 24, 36, 48 and 72 h after drug administration. After 1 h, all urine samples were negative for rhEPO, whereas 40% of DBS samples were considered suspicious. All samples between 10 and 48 h were suspicious for the presence of Eporatio®, except one urine sample that was negative at 48 h. After 72 h, 40% of urine samples and 60% of DBS samples were suspicious and would have proceeded to a confirmation analysis. DBS is an efficient complementary matrix to urine for detection of rhEPO micro-doses.

Download full-text PDF

Source
http://dx.doi.org/10.1002/dta.3651DOI Listing

Publication Analysis

Top Keywords

dbs samples
20
dried blood
8
samples
8
eporatio® urine
8
urine samples
8
urine
6
dbs
6
evaluation single
4
eporatio®
4
single eporatio®
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!