Purpose: To report the development of a new sacroiliac joint (SIJ) arthrodesis system that can be used for isolated fusion of the SIJ and, unlike known implant systems, in combination with lumbar instrumentation or as an alternative to existing sacropelvic fixation (SPF) methods, and the patient-reported outcomes in two cases.

Materials And Methods: After a comprehensive review of 207 pelvic computed tomography (CT) datasets, an implant body was designed. Its shape was modeled based on the SIJ recess. A screw anchored in the ilium secures the position of the implant and allows connection to lumbar instrumentation. Two patients with confirmed SIJ syndrome underwent surgery with the anatomically adapted implant. They were evaluated preoperatively, 6 months, and 12 months postoperatively. Visual Analogue Scale (VAS), Oswestry Disability Index (ODI), Million Visual Analogue Scale (MVAS), Roland Morris Score (RMS), reduction of SIJ/leg pain, and work status were assessed. Bony fusion of the SIJ was evaluated by radiographs and CT 12 months after the procedure.

Results: Analysis of pelvic CT data revealed a wedge-shaped implant body in four different sizes. In the two patients, VAS decreased from 88 to 33 points, ODI improved from 67 to 35%, MVAS decreased from 80 to 36%, and RMS decreased from 18 to 9 points 12 months after surgery. SIJ pain reduction was 80% and 90%, respectively. Follow-up CT and radiographs showed solid bony integration.

Conclusion: The implant used takes into account the unique anatomy of the SIJ and also meets the requirements of a true arthrodesis. Initial results in two patients are promising. Biomechanical and clinical studies will have to show whether the considerable theoretical advantages of the new implant system over existing SIJ implants - in particular the possibility of connection to a lumbar stabilization system - and SPFs can be put into practice.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10840548PMC
http://dx.doi.org/10.2147/ORR.S434566DOI Listing

Publication Analysis

Top Keywords

sacroiliac joint
12
patient-reported outcomes
8
sij
8
fusion sij
8
lumbar instrumentation
8
implant body
8
connection lumbar
8
visual analogue
8
analogue scale
8
decreased points
8

Similar Publications

Postpartum pyogenic sacroiliitis masquerading as sciatic neuropathy.

BMJ Case Rep

January 2025

Department of Orthopedics, SDM College of Medical Sciences and Hospital, Shri Dharmasthala Manjunatheshwara University, Dharwad, Karnataka, India.

Low back pain is common in women, especially during pregnancy and puerperium. Septic sacroiliitis, a rare cause of back pain in the postpartum period can mimic other common causes of low back pain like muscle strain, urinary tract infection, pelvic inflammatory disease, endometritis and intervertebral disc prolapse. The proximity of the sacroiliac joint to the sacral nerve plexus results in septic sacroiliitis frequently presenting with symptoms mimicking intervertebral disc prolapse.

View Article and Find Full Text PDF

Objective: Aim: Study the mechanism of interaction between the 'sacroiliac joint - screw' system and determine the optimal parameters of the stabilizing structure, the strength of the system connection through computer modeling, and anatomical-biomechanical experiment.

Patients And Methods: Materials and Methods: The optimal parameters of the stabilizing structure for the sacroiliac joint were calculated using software package MathCAD. To validate the results of the numerical modeling, corresponding investigations of mechanical characteristics and determination of stiffness of the studied systems were conducted by an upgraded testing stand, TIRAtest-2151.

View Article and Find Full Text PDF

Objectives: To assess the ability of a previously trained deep-learning algorithm to identify the presence of inflammation on MRI of sacroiliac joints (SIJ) in a large external validation set of patients with axial spondyloarthritis (axSpA).

Methods: Baseline SIJ MRI scans were collected from two prospective randomised controlled trials in patients with non-radiographic (nr-) and radiographic (r-) axSpA (RAPID-axSpA: NCT01087762 and C-OPTIMISE: NCT02505542) and were centrally evaluated by two expert readers (and adjudicator in case of disagreement) for the presence of inflammation by the 2009 Assessment of SpondyloArthritis International Society (ASAS) definition. Scans were processed by the deep-learning algorithm, blinded to clinical information and central expert readings.

View Article and Find Full Text PDF

Introduction: Sacroiliac joint (SIJ) dislocations, particularly pure SIJ dislocations without associated fractures, represent a rare and complex subset of pelvic ring injuries. Given the intricate pelvic anatomy and the need to achieve both stability and functional recovery, the optimal surgical management for these injuries remains a topic of debate. This systematic review aims to evaluate the various surgical techniques employed in treating this rare and challenging injury and assess associated clinical outcomes and complications.

View Article and Find Full Text PDF

Background: Open pelvic fractures are rare but represent a serious clinical problem with high mortality rates. Acute mortality is often associated with hemorrhage, whereas delayed mortality is most often associated with sepsis and multiple organ failure. We report a case of Wang's classification of type II open pelvic ring fracture with hemorrhagic shock and septic shock from gas gangrene.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!