A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparative and stability study of glucose concentrations measured in both sodium fluoride and serum separator tubes. | LitMetric

Introduction: Sodium fluoride/potassium oxalate (NaF/KOx) tubes has been regarded as the gold-standard tubes for glucose analysis. Even though their ineffectiveness in immediately inhibiting glycolysis has been reported in several studies especially in the first 1-4h, they are still used in our clinical biochemistry laboratory for glucose measurement. However, in its absence, only serum separator tubes are employed for glucose measurement. We aim to determine whether serum separator tubes (SSTs) can replace NaF/KOx tubes for laboratory measurement of blood glucose and to assess the stability of glucose concentrations for 3 days period.

Methods And Findings: NaF/KOx tube type was the reference method while SSTs type was the candidate method for glucose measurement. A total of 50 paired samples collected separately in NaF/KOx tubes and SSTs from healthy adult participants in the Gambia Adults Reference Intervals Study (GARIS) project were used as the project sample size. Following blood collection and separation, the glucose concentration was measured within 2 h, and at 24h, 42h and 72h time-points. Our data analysis showed no significant difference in the mean glucose concentrations between the reference tube and candidate tube types (Mean difference = 0.06 mmol/L; P = 0.38) recorded in the different timepoints. Using growth trajectory and mixed effects model, the study data further showed no significant change in the glucose concentrations (p = 0.25) for three days period.

Conclusions: The study confirms that SSTs can produce similar glucose results when employed in the absence of NaF/KOx tubes. Besides, the glucose concentrations were stable in both tubes for three days when the samples were separated within 2 h and refrigerated in 2-8°C.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10832486PMC
http://dx.doi.org/10.1016/j.plabm.2024.e00360DOI Listing

Publication Analysis

Top Keywords

glucose concentrations
20
naf/kox tubes
16
glucose
12
serum separator
12
separator tubes
12
glucose measurement
12
tubes
9
tubes glucose
8
tubes ssts
8
three days
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!