Carbon monoxide impurities in hydrogen detected with resonant photoacoustic cell using a mid-IR laser source.

Photoacoustics

State Key Laboratory of Quantum Optics and Quantum Optics Devices, Institute of Laser Spectroscopy, Shanxi University, Taiyuan 030006, China.

Published: April 2024

We report on a photoacoustic sensor system based on a differential photoacoustic cell to detect the concentration of CO impurities in hydrogen. A DFB-QCL laser with a central wavelength of 4.61 µm was employed as an exciting source with an optical power of 21 mW. Different concentrations of CO gas mixed with pure hydrogen were injected into the photoacoustic cell to test the linear response of the photoacoustic signal to the CO concentration. The stability of the long-term operation was verified by Allan-Werle deviation analysis. The minimum detection limit (MDL, SNR=1) results 8 ppb at 1 s and reaches a sub-ppb level at 100 s of integration time. Dynamic response of the system is linear and has been tested up to the concentration of 6 ppm. Saturation conditions are expected to be reached for CO concentration larger than 100 ppm.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10830886PMC
http://dx.doi.org/10.1016/j.pacs.2024.100585DOI Listing

Publication Analysis

Top Keywords

photoacoustic cell
12
impurities hydrogen
8
photoacoustic
5
carbon monoxide
4
monoxide impurities
4
hydrogen detected
4
detected resonant
4
resonant photoacoustic
4
cell mid-ir
4
mid-ir laser
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!