Although physical grids improve contrast in radiographic images by reducing scattered radiation, various artifacts such as grid shadow, moire, and cutoff result in increased patient doses. To overcome these problems, this study evaluates the applicability and usefulness of a material thickness-based scatter-correction technique for mammography. Specifically, this study aims to compare and evaluate the performance of mammography using the proposed software-based scatter correction framework and a physical grid. The proposed technique enables scatter correction based on pre-calculated parameters of a thickness-based scatter kernel at a water slab phantom and an empirical quantity of scatter components in a mammographic system. In the Monte Carlo simulation and experiment, the proposed framework displayed an intensity profile and full width at half maximum that closely approximated those seen in the physical grid. In addition, by applying the proposed framework to the ACR phantom, it was verified that all structures, including specks, were distinctly distinguished. The results demonstrate that the X-ray scatter-correction method with a software-based framework for mammography is applicable to the field of diagnostic imaging, as this approach yields image quality equivalent to that achieved with physical grids while also enabling a reduction in radiation doses for patients.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10835378 | PMC |
http://dx.doi.org/10.1016/j.heliyon.2024.e24862 | DOI Listing |
Phys Rev Lett
December 2024
University of Maryland, NIST, Joint Center for Quantum Information and Computer Science, /, College Park, Maryland 20742, USA.
Diatomic molecular codes [V. V. Albert, J.
View Article and Find Full Text PDFPhys Chem Chem Phys
January 2025
The University of New South Wales, Kensington, Australia.
Correction for 'Formulation and mechanism of copper tartrate - a novel anode material for lithium-ion batteries' by Matthew Teusner , , 2023, , 21436-21447, https://doi.org/10.1039/D3CP02030D.
View Article and Find Full Text PDFCoherent heterodyne lidars are typically used for windspeed and attenuated backscattering measurements. The lack of molecular backscattering detection capability has limited the calibrated backscattering measurements until recent advances in coherent lidar technology. In this work, the simultaneous detection of aerosol and molecular backscattering is demonstrated with coherent heterodyne lidar, and the results are compared with a state-of-the-art Raman lidar PollyXT as a reference in a long-range for the first time.
View Article and Find Full Text PDFUnderwater optical imaging, especially in coastal waters, suffers from reduced spatial resolution and contrast by forward scattered light. With the increased number of hyper- and multi-spectral imaging applications, the effect of the point spread function (PSF) at different spectral bands becomes increasingly more relevant. In this work, extensive laboratory measurements of the PSF at 450, 500, 550, 600 and 650 nm in different turbidity have been carried out.
View Article and Find Full Text PDFA compact and easy-to-use high-bandwidth autobalanced detector for microscopy is presented, being able to remove up to 67 dB of correlated noise, thus, allowing for shot-noise limited image acquisition even in the presence of high laser excess noise. Detecting a 20 MHz modulation frequency at half the repetition rate of the driving pulsed laser, the autobalanced detector is able to exploit an extra +3 dB increase in signal-to-noise ratio due to the coherent addition of modulation sidebands in stimulated Raman scattering. Pixel-by-pixel noise canceling and correction of sample transmission losses are possible for pixel scan rates of more than 1.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!