Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: To increase understanding of optimal imaging parameters [ 18 F]PSMA-1007 when imaging patients with prostate cancer and to determine interrater agreement using [ 18 F]PSMA-1007.
Methods: In this observational study, four independent physicians read reconstruction sets using bedtimes of 1, 2 and 3 minutes of patients undergoing [ 18 F]PSMA-1007. positron emission topography. Clear and equivocal lesions and their locations were recorded. Image noise was rated on a four-point scale. Lesion counts were compared using inter-class correlation whereas noise ratings were compared using generalized estimating equations. Repeated cases were used to assess intra-rater agreement.
Results: Sixty reconstruction sets of 16 consecutively examined participants were included. Participants had a mean age of 71.5 years, six of them were examined prior to any treatment, three had a history of radiotherapy and seven of prostatectomy. Median Gleason score of primary tumors was 7. Imaging was performed after a mean of 132 min using a mean 3.95 MBq/Kg body weight of [ 18 F] PSMA-1007. Neither the total number of lesions per location nor the proportion of equivocal lesions varied consistently between bedtimes. Inter-rater reliability scores varied depending on location from 0.40 to 1.0 and were similar for all bedtimes. Intra-rater reliability varied between 0.70 and 0.76 for the three different bedtimes. Noise ratings were significantly lower for 1 minute than 3 minutes per bed.
Conclusion: In the setting of [ 18 F]PSMA-1007 PET CT, 1, 2 and 3 minutes per bed produce similar results unlikely to affect clinical interpretation. Image noise ratings favor 2 and 3 minutes per bed.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/MNM.0000000000001823 | DOI Listing |