Two-year outcomes of anterior versus posterior scleral application of mitomycin C-soaked sponge in trabeculectomy.

Jpn J Ophthalmol

State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Sun Yat-sen University, No. 7 Jinsui Road, Guangzhou, 510060, China.

Published: March 2024

Purpose: To compare the safety and efficacy of two different application methods of mitomycin C (MMC)-soaked sponge in trabeculectomy.

Study Design: Retrospective study.

Methods: We included 71 eyes of 71 patients that had undergone trabeculectomy. In the anterior scleral application group, 36 eyes were treated using the long side of the MMC-soaked sponge placed parallel to the limbus. The efficacy and safety in these eyes were compared with eyes treated with the posterior scleral application group, consisting of 35 eyes treated with the long side of the MMC-soaked sponge placed perpendicular to the limbus. The follow-up period was 2 years. The safety of the procedure, including bleb morphology and complications, was the primary outcome, while the success rate was the secondary outcome.

Results: The cumulative success rate at 2 years postoperatively was 94.4% in the anterior and and 94.3% in the posterior scleral application group (P = 1.000). However, with the posterior scleral application of the MMC-soaked sponge, blebs were more low-lying (P = 0.048), less in extent (P < 0.001), more normally vascularized (P = 0.027) and more posteriorly directed (P < 0.001). Furthermore, the incidence of thin-walled cystic bleb (P = 0.028) and bleb leakage (P = 0.025) was significantly lower in the posterior scleral application group than in the anterior group.

Conclusion: Although there were similar success rates, the posterior scleral application of MMC-soaked sponge with trabeculectomy was safer with a better bleb morphology than the anterior scleral application.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10384-023-01043-1DOI Listing

Publication Analysis

Top Keywords

scleral application
32
posterior scleral
24
mmc-soaked sponge
20
application group
16
eyes treated
12
application
9
scleral
8
sponge trabeculectomy
8
anterior scleral
8
treated long
8

Similar Publications

Purpose: Osteogenesis imperfecta (OI) is a rare hereditary disorder of the connective tissue. Despite recent attention to corneal abnormalities in OI, understanding remains limited. This study aimed to comprehensively evaluate corneal changes in a large sample of OI patients compared to controls using in vivo confocal microscopy (IVCM).

View Article and Find Full Text PDF

Purpose: To evaluate the refractive prediction error of common intraocular lens (IOL) power calculation formulas in patients who underwent intrascleral IOL fixation using the four-flanged technique.

Methods: This prospective, longitudinal, single-site, single-surgeon study's setting was the Department for Ophthalmology and Optometry, Medical University of Vienna, Austria. Patients who received IOL implantation via the four-flanged technique were followed up to 3 months after the operation.

View Article and Find Full Text PDF

To assess and compare the results of pars plana vitrectomy (PPV) with short-term perfluorocarbon liquid (PFCL) tamponade and combined PPV with scleral buckling to treat rhegmatogenous retinal detachment (RRD) with inferior retinal breaks complicated by proliferative vitreoretinopathy (PVR). The medical records of patients who had vitreoretinal surgery for RRD with inferior retinal breaks complicated by PVR were reviewed. Group 1 had PPV with PFCL, and Group 2 had PPV with scleral buckling.

View Article and Find Full Text PDF

Background: Ocular following responses (OFRs)-small-amplitude, short-latency reflexive eye movements-have been used to study visual motion processing, with potential diagnostic applications. However, they are difficult to record with commercial, video-based eye trackers, especially in children.

Objective: We aimed to design and develop a noninvasive eye tracker specialized for measuring OFRs, trading off lower temporal resolution and a smaller range for higher spatial resolution.

View Article and Find Full Text PDF

[Application progress of micropulse wave transscleral laser treatment in glaucoma].

Zhonghua Yan Ke Za Zhi

December 2024

Aier Glaucoma Institute, Hunan Engineering Research Center for Glaucoma with Artificial Intelligence in Diagnosis and Application of New Materials, Changsha Aier Eye Hospital, Changsha410015, China.

Glaucoma is the leading cause of blindness worldwide, and reducing intraocular pressure is crucial to delaying its progression. This review aims to explore the application progress of micropulse wave transscleral laser treatment (mTLT) in the treatment of glaucoma. This article introduces the evolution of ciliary body destructive surgical methods, and focuses on the mechanism of mTLT in the treatment of glaucoma, including reducing aqueous humor production, increasing the uveoscleral pathway and trabecular meshwork pathway for aqueous humor outflow.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!