The use of appropriately sized implants is critical for achieving optimal gap balance following total knee arthroplasty (TKA). Inappropriately sized implants could result in several complications. Robot-assisted TKA (RA-TKA) using CT-based pre-operative planning predicts implant sizes with high accuracy. There is scant literature describing the accuracy of image-free RA-TKA in predicting implant sizes. The purpose of this study was to assess the accuracy of an image-free robotic system in predicting implant sizes during RA-TKA. Patients who underwent cruciate-retaining RA-TKA for primary osteoarthritis, using an image-free hand-held robotic system were studied. The predicted and implanted sizes of the femoral component, tibial component and polyethylene insert, for 165 patients, were recorded. Agreement between robot-predicted and implanted component sizes was assessed in percentages, while reliability was assessed using Cohen's weighted kappa coefficient. The accuracy of the robotic system was 63% (weighted-kappa = 0.623, P < 0.001), 94% (weighted-kappa = 0.911, P < 0.001) and 99.4% (weighted-kappa = 0.995, P < 0.001), in predicting exact, ± 1 and ± 2 sizes of the femoral component, respectively. For the tibial component, an accuracy of 15.8% (weighted-kappa = 0.207, P < 0.001), 55.8% (weighted-kappa = 0.378, P < 0.001) and 76.4% (weighted-kappa = 0.568, P < 0.001) was noted, for predicting exact, ± 1 and ± 2 sizes respectively. An accuracy of 88.5%, 98.2% and 100%, was noted for predicting exact, ± 1 and ± 2 sizes of the polyethylene insert respectively. Errors in predicting accurate implant sizes could be multi-factorial. Though the accuracy of image-free RA-TKA with respect to alignment and component positioning is established, the surgeon's expertise should be relied upon while deciding appropriate implant sizes.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11701-024-01818-9DOI Listing

Publication Analysis

Top Keywords

implant sizes
16
robotic system
16
total knee
8
knee arthroplasty
8
image-free hand-held
8
hand-held robotic
8
sized implants
8
accuracy image-free
8
predicting implant
8
sizes
6

Similar Publications

The Biological Properties of Co-Doped Monetite Are Influenced by Thermal Treatment.

J Biomed Mater Res B Appl Biomater

February 2025

Bioassays and Cellular Dynamics Lab, Department of Chemical and Biological Sciences, Institute of Biosciences, UNESP: São Paulo State University, São Paulo, Brazil.

Calcium phosphates, notably monetite, are valued biomaterials for bone applications owing to their osteogenic properties and rapid uptake by bone cells. This study investigates the enhancement of these properties through Cobalt doping, which is known to induce hypoxia and promote bone cell differentiation. Heat treatments at 700°C, 900°C, and 1050°C are applied to both monetite and Cobalt-doped monetite, facilitating the development of purer, more crystalline phases with varied particle sizes and optimized cellular responses.

View Article and Find Full Text PDF

Purpose: There are no universally established guidelines for material selection in orbital wall fracture reconstruction. With an increasing preference for permanent implants, this study aimed to compare the long-term clinical outcomes of three different non-resorbable materials in reconstructing isolated orbital floor fractures.

Design: A retrospective, interventional comparative study.

View Article and Find Full Text PDF

Development of Prevascularized Synthetic Block Graft for Maxillofacial Reconstruction.

J Funct Biomater

January 2025

Center for Oral, Clinical and Translational Sciences, Faculty of Dentistry, Oral & Craniofacial Sciences, King's College London, London SE1 9RT, UK.

Cranio-maxillofacial bone reconstruction, especially for large defects, remains challenging. Synthetic biomimetic materials are emerging as alternatives to autogenous grafts. Tissue engineering aims to create natural tissue-mimicking materials, with calcium phosphate-based scaffolds showing promise for bone regeneration applications.

View Article and Find Full Text PDF

Transcatheter aortic valve replacement (TAVR) in patients with severe aortic stenosis and raphe-type bicuspid aortic valve (BAV) is still associated with poor outcomes in terms of increased risk of paravalvular regurgitation, stroke, and permanent pacemaker implantation. There is no definitive consensus on the optimal sizing method for prosthesis selection in this setting. The LIRA method is a supra-annular tailored sizing method specifically designed for bicuspid anatomy that might increase accuracy of prosthesis choice in BAV patients and improve TAVR outcomes.

View Article and Find Full Text PDF

Under benign conditions, bone tissue can regenerate itself without external intervention. However, this regenerative capacity can be compromised by various factors, most importantly related with the extent of the injury. Critical-sized defects, exceeding the body's natural healing ability, demand the use of temporary or permanent devices like artificial joints or bone substitutes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!