Tableting of coated multiparticulates: Influences of punch face configurations.

Int J Pharm

GEA-NUS Pharmaceutical Processing Research Laboratory, Department of Pharmacy, National University of Singapore, 18 Science Drive 4, Singapore 117543, Singapore.

Published: March 2024

The influences of the punch face design on multi-unit pellet system (MUPS) tablets were investigated. Drug-loaded pellets coated with sustained release polymer based on ethylcellulose or acrylic were compacted into MUPS tablets. Punch face designs used include standard concave, deep concave, flat-faced bevel edge and flat-faced radius edge. MUPS tablets compacted at 2 or 8 kN were characterized for their tensile strength. The extent of pellet coat damage after tableting was evaluated from drug release profiles. Biconvex tablets were weaker by 0.01-0.15 MPa, depending on the pellet type used, and had 1-17 % higher elastic recovery (p < 0.000) than flat-faced tablets. At higher compaction force, the use of the deep concave punch showed a 13-26 % lower extent of pellet coat damage, indicated by a relatively higher mean dissolution time, compared to other punch face configurations (p < 0.000). This was attributed to increased rearrangement energy of the compacted material due to the high punch concavity, which sequestered compaction stress exerted on pellet coats. Although the deep concave punch reduced the stress, the resultant tablets containing pellets coated with acrylic were weaker (p = 0.01). Overall, the punch face configuration significantly affected the quality of MUPS tablets.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijpharm.2024.123863DOI Listing

Publication Analysis

Top Keywords

punch face
12
mups tablets
12
influences punch
8
tableting coated
4
coated multiparticulates
4
multiparticulates influences
4
face configurations
4
configurations influences
4
face design
4
design multi-unit
4

Similar Publications

Background: Injectable biostimulator treatments stimulate endogenous collagen in aging skin, but whether they act through similar pathways is unknown. This study evaluates two biostimulatory agents' effects on genes, expressed proteins, and respective pathways as potential aging biomarkers and treatment outcomes.

Methods: This 13-week, randomized, single-center, comparative study compared volume change and gene expression stimulated by poly-L-lactic acid (PLLA-SCATM) and calcium hydroxylapatite (CaHA-R) via punch biopsy in the nasolabial fold (NLF).

View Article and Find Full Text PDF

Punch-marked coins (PMCs) are the oldest coins in India and among the most widely circulated globally, often found in hoards that highlight their extensive use. This study utilizes X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS) to analyze the surface elemental composition and chemical properties of nine series (S-0 to S-VIII) of Janapada (S-0) and imperial PMCs (S-1 to S-VIII) dating from 600 to 200 BCE, housed in the Numismatic Society of India at BHU, Varanasi, based on the Gupta-Hardakar classification related to the PMCs. XRD results reveal four prominent diffraction peaks corresponding to metallic silver (Ag) in the face-centred cubic (fcc) phase, with a slight variation in d-spacing (∼ 0.

View Article and Find Full Text PDF

Background: Millions experience inadequately managed acute pain each year. Opioids are an important tool for managing pain; however, recent reductions in opioid prescriptions have exacerbated preexisting challenges in pain management. Moreover, patient expectations and desires for pain management may drive additional opioid use.

View Article and Find Full Text PDF
Article Synopsis
  • A study was conducted to compare the genetic effects of two injectable biostimulators, poly l-lactic acid (PLLA-SCA) and calcium hydroxylapatite (CaHA-R), on facial aging signs over 13 weeks in 21 participants.
  • Results indicated that PLLA-SCA influenced gene expression related to fat cell regeneration, while CaHA-R did not show this effect.
  • The findings suggest that PLLA-SCA could lead to longer-lasting skin improvements and better overall skin health due to its unique regenerative mechanisms.
View Article and Find Full Text PDF

A direct punch with a clenched fist to the face most often results in soft tissue damage, which is usually not serious enough to be considered a severe health impairment. This article presents two cases in which a single punch to the orbital region led to a blowout fracture. The first case resulted in additional displacement of the right lens into the vitreous body, secondary glaucoma and retinal detachment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!