Towards liquid EPR dosimetry using nitroxides in aqueous solution.

Phys Med Biol

Department of Chemistry and Konstanz Research School Chemical Biology, University of Konstanz, Konstanz, Germany.

Published: February 2024

. Water-equivalent dosimeters are desirable for dosimetry in radiotherapy. The present work investigates basic characteristics of novel aqueous detector materials and presents a signal loss approach for electron paramagnetic resonance (EPR) dosimetry.. The proposed principle is based on the radiation dose dependent annihilation of EPR active nitroxides (NO·) in aqueous solutions. Stable nitroxide radicals (3-Maleimido-2,2,5,5-tetramethyl-1-pyrrolidinyloxy (MmP), 3-Carbamoyl-2,2,5,5-tetramethyl-1-pyrrolidinyloxy (CmP)) in aqueous solutions containing dimethyl sulfoxide (DMSO) as an additive were filled in glass capillaries for irradiation and EPR readout. Radiation doses ranging from 1 to 64 Gy were applied with a clinical 6 MV flattening filter free photon beam. EPR readout was then performed with a X-band benchtop spectrometer. The dose response, temporal stability and reproducibility of the samples' EPR signal amplitudes as well as the influence of the nitroxide concentration between 10 and 160M on the absolute signal loss were investigated using MmP. CmP was used to examine the dependence of the dose response on DMSO concentration between 0 and 10 vol%. An indirect effect model was fitted to the experimental data assuming irradiation induced radical reactions as the underlying mechanism.. For an initial MmP concentration of 20M, absolute EPR signal loss is linear up to a dose of 16 Gy with a yield G(-NO·) of approximately 0.4mol J. Within five weeks upon sample irradiation to doses between 0 and 32 Gy relative EPR signal fluctuations were on average (126 readouts) below 1% (1). For c(MmP) ≥ 20M, absolute signal loss is only weakly dependent on c(MmP), whereas it increases strongly with increasing c(DMSO) in the range 0-5 vol%. An indirect effect model is applicable to describe the reaction mechanism resulting in the observed dose response curve.. Liquids consisting of nitroxides in aqueous solution and small amounts of DMSO (2 vol%) show promising basic characteristics for application as water-equivalent EPR dosimeter materials in radiotherapy. The EPR signal loss is based on an indirect effect mediated by diffusing radicals originating from the radiolysis of the water/DMSO mixture.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/ad25c4DOI Listing

Publication Analysis

Top Keywords

signal loss
20
epr signal
16
dose response
12
epr
9
epr dosimetry
8
nitroxides aqueous
8
aqueous solution
8
basic characteristics
8
aqueous solutions
8
epr readout
8

Similar Publications

To improve the expressiveness and realism of illustration images, the experiment innovatively combines the attention mechanism with the cycle consistency adversarial network and proposes an efficient style transfer method for illustration images. The model comprehensively utilizes the image restoration and style transfer capabilities of the attention mechanism and the cycle consistency adversarial network, and introduces an improved attention module, which can adaptively highlight the key visual elements in the illustration, thereby maintaining artistic integrity during the style transfer process. Through a series of quantitative and qualitative experiments, high-quality style transfer is achieved, especially while retaining the original features of the illustration.

View Article and Find Full Text PDF

Stock price prediction is a challenging research domain. The long short-term memory neural network (LSTM) widely employed in stock price prediction due to its ability to address long-term dependence and transmission of historical time signals in time series data. However, manual tuning of LSTM parameters significantly impacts model performance.

View Article and Find Full Text PDF

Eccentric contraction- (ECC) induced force loss is a hallmark of murine dystrophin-deficient (mdx) skeletal muscle that is used to assess efficacy of potential therapies for Duchenne muscular dystrophy. While virtually all key proteins involved in muscle contraction have been implicated in ECC force loss, a unifying mechanism that orchestrates force loss across such diverse molecular targets has not been identified. We showed that correcting defective hydrogen sulfide (H2S) signaling in mdx muscle prevented ECC force loss.

View Article and Find Full Text PDF

The CDKN2A gene, responsible for encoding the tumor suppressors p16(INK4A) and p14(ARF), is frequently inactivated in non-small cell lung cancer (NSCLC). Herein, an uncharacterized long non-coding RNA (lncRNA) (ENSG00000267053) on chromosome 19p13.12 was found to be overexpressed in NSCLC cells with an active, wild-type CDKN2A gene.

View Article and Find Full Text PDF

Introduction: Individuals with hearing loss and hearing aid users report higher levels of listening effort and fatigue in daily life compared with those with normal hearing. However, there is a lack of objective measures to evaluate these experiences in real-world settings. Recent studies have found that higher sound pressure levels (SPL) and lower signal-to-noise ratios (SNR) are linked to increased heart rate and decreased heart rate variability, reflecting the greater effort required to process auditory information.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!