Introduction: We have previously adapted a clinical linear accelerator (Elekta Precise, Elekta AB) for ultra-high dose rate (UHDR) electron delivery. To enhance reliability in future clinical FLASH radiotherapy trials, the aim of this study was to introduce and evaluate an upgraded beam control system and beam tuning process for safe and precise UHDR delivery.
Materials And Methods: The beam control system is designed to interrupt the beam based on 1) a preset number of monitor units (MUs) measured by a monitor detector, 2) a preset number of pulses measured by a pulse-counting diode, or 3) a preset delivery time. For UHDR delivery, an optocoupler facilitates external control of the accelerator's thyratron trigger pulses. A beam tuning process was established to maximize the output. We assessed the stability of the delivery, and the independent interruption capabilities of the three systems (monitor detector, pulse counter, and timer). Additionally, we explored a novel approach to enhance dosimetric precision in the delivery by synchronizing the trigger pulse with the charging cycle of the pulse forming network (PFN).
Results: Improved beam tuning of gun current and magnetron frequency resulted in average dose rates at the dose maximum at isocenter distance of >160 Gy/s or >200 Gy/s, with or without an external monitor chamber in the beam path, respectively. The delivery showed a good repeatability (standard deviation (SD) in total film dose of 2.2%) and reproducibility (SD in film dose of 2.6%). The estimated variation in DPP resulted in an SD of 1.7%. The output in the initial pulse depended on the PFN delay time. Over the course of 50 measurements employing PFN synchronization, the absolute percentage error between the delivered number of MUs calculated by the monitor detector and the preset MUs was 0.8 ± 0.6% (mean ± SD).
Conclusion: We present an upgraded beam control system and beam tuning process for safe and stable UHDR electron delivery of hundreds of Gy/s at isocenter distance at a clinical linac. The system can interrupt the beam based on monitor units and utilize PFN synchronization for improved dosimetric precision in the dose delivery, representing an important advancement toward reliable clinical FLASH trials.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10830783 | PMC |
http://dx.doi.org/10.3389/fonc.2024.1342488 | DOI Listing |
Clin Transl Oncol
January 2025
Department of Radiation Oncology, HM Hospitales, Madrid, Spain.
Introduction: SRS for the treatment of limited brain metastases (BM) is widely accepted, but there are still limitations in the management of numerous BM. Frameless single-isocenter multitarget SRS is a novel technique that allows for rapid treatment delivery to multiple BM. We report our preliminary clinical, dosimetric, and patient´s shifts outcomes with this technique.
View Article and Find Full Text PDFPurpose: The degenerative joint disease is a temporomandibular disorder. By analysing texture parameters, it becomes possible to characterize and differentiate various tissues, based on their textural properties according to cone-beam computed tomography (CBCT). This study evaluated degenerative diseases in the temporomandibular joint through texture analysis.
View Article and Find Full Text PDFBraz Oral Res
January 2025
Pontifícia Universidade Católica de Minas Gerais - PUC Minas, School of Dentistry, Graduate Program in Dentistry, Belo Horizonte, MG, Brazil.
The aim of this cross-sectional study was to perform a three-dimensional (3D) assessment of the cranial base of patients with unilateral cleft lip and palate (UCLP). Cone-beam computed tomography (CBCT) scans of 52 UCLP patients (21 females and 31 males; mean age, 10.0 ± 2.
View Article and Find Full Text PDFClin Implant Dent Relat Res
February 2025
Department of Implantology, The Affiliated Hospital of Stomatology, School of Stomatology, Zhejiang University School of Medicine, Hangzhou, China.
Objectives: This study aimed to assess the effects of deproteinized bovine bone mineral with collagen (DBBMC) combined with deproteinized bovine bone mineral (DBBM) on facial alveolar bone augmentation in the anterior maxillary region.
Materials And Methods: Patients receiving dental implant placement with simultaneous lateral bone augmentation using DBBM (control group) or DBBMC combined with DBBM (test group) were included in the study. The radiographic assessment of facial alveolar bone, such as facial horizontal bone thickness (FHBT), facial vertical bone level (FVBL), and square of facial bone (SFB), was taken by cone beam computed tomography (CBCT).
Lab Anim Res
January 2025
Anatomy Department, Faculty of Basic Medical Sciences, Alex Ekwueme, Federal University, Ndufu-Alike, Ebonyi State, Nigeria.
Background: The Microtubules-associated protein tau (MAPT), alpha-synuclein (SNCA), and leucine zipper tumor suppressor 3 (LZTS3) genes are implicated in neurodegeneration and tumor suppression, respectively. This study investigated the regulatory roles of eugenol on paraquat-altered genes.
Results: Forty male Wistar rats divided into five groups of eight rats were used.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!