Reproducibility of Laser Doppler Flowmetry in gingival microcirculation. A study on six different protocols.

Microvasc Res

Department of Oral and Maxillofacial Surgery, Linköping University Hospital, Linköping, Sweden; Department of Biomedical and Clinical Sciences (BKV), Linköping University, Linköping, Sweden. Electronic address:

Published: May 2024

Objectives: Laser Doppler Flowmetry (LDF) is a non-invasive technique for the assessment of tissue blood flow, but increased reproducibility would facilitate longitudinal studies. The aim of the study was to assess the interday reproducibility of Laser Doppler Flowmetry (LDF) at rest, at elevated local temperatures, and with the use of the vasodilator Methyl Nicotinate (MN) in six interconnected protocols for the measurement of the blood supply to the microvascular bed of the gingiva.

Methods: Ten healthy volunteers were included. Interweek LDF measurements with custom-made acrylic splints were performed. Six protocols were applied in separate regions of interest (ROI): 1; basal LDF, 2; LDF with thermoprobe 42 °C, 3; LDF with thermoprobe 45 °C, 4; LDF with thermoprobe 42 °C and MN, 5; LDF with thermoprobe 45 °C and MN and 6; LDF with MN.

Results: Intra-individual reproducibility was assessed by the within-subject coefficient of variation (wCV) and the intraclass correlation coefficient (ICC). Basal LDF measurements demonstrated high reproducibility with wCV 11.1 in 2 min and 10.3 in 5 min. ICC was 0.9 and 0.92. wCV after heat and MN was 4.9-10.3 and ICC 0.82-0.93. The topically applied MN yielded increased blood flow.

Conclusion: This is the first study evaluating the reproducibility of basal LDF compared to single or multiple vasodilatory stimuli in gingiva. Multiple collector fibers probe and stabilizing acrylic splints are recommended. Vasodilatory stimulation showed a tendency toward higher reproducibility. Furthermore, MN yields vasodilation in gingiva.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.mvr.2024.104666DOI Listing

Publication Analysis

Top Keywords

ldf thermoprobe
16
laser doppler
12
doppler flowmetry
12
basal ldf
12
ldf
11
reproducibility laser
8
flowmetry ldf
8
ldf measurements
8
acrylic splints
8
thermoprobe 42 °c
8