Objectives: In patients with unresectable malignant hilar biliary obstruction (UMHBO), drainage of ≥ 50% liver volume correlates with better clinical outcomes. Accurately measuring the liver volume to be drained by biliary stents is required. We aimed to develop a novel method for calculating the drained liver volume (DLV) using a 3D volume analyzer (3D volumetry), and assess the usefulness for drainage in patients with UMHBO.

Methods: Three-dimensional volumetry comprises the following steps: (1) manual tracing of bile duct using 3D imaging system; (2) 3D reconstruction of bile duct and liver parenchyma; and (3) calculating DLV according to the 3D distribution of bile ducts. Using 3D volumetry, we reviewed data of patients who underwent biliary drainage for UMHBO, calculated the DLV, and determined the association between DLV and biliary drainage outcome.

Results: There were 104 eligible cases. The mean DLV was 708 ± 393 ml (53% ± 21%). and 65 patients (63%) underwent drainage of   ≥50% liver volume. The clinical success rate was significantly higher in patients with DLV ≥ 50% than in patients with DLV < 50% (89% vs. 28%, P < 0.001). The median time to recurrence of biliary obstruction (TRBO) and survival time were significantly longer in patients with DLV ≥ 50% than in patients with DLV < 50% (TRBO, 292 vs. 119 days, P = 0.03; survival, 285 vs. 65days, P = 0.004, log-rank test, respectively).

Conclusions: Three-dimensional volumetry, a novel method to calculate DLV accurately according to bile duct distribution was useful for drainage in UMHBO patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10960883PMC
http://dx.doi.org/10.1007/s10620-024-08294-zDOI Listing

Publication Analysis

Top Keywords

liver volume
20
biliary drainage
12
novel method
8
method calculating
8
calculating drained
8
drained liver
8
volume analyzer
8
unresectable malignant
8
malignant hilar
8
hilar biliary
8

Similar Publications

Introduction: Pediatric liver transplantation provides substantial survival benefit. An emphasis on value-based practices has become a central theme in many surgical fields, but have not been well-studied in pediatric transplantation. Given an increasing focus on optimizing outcomes while containing costs, defining value in pediatric liver transplantation warrants investigation.

View Article and Find Full Text PDF

Follicular lymphoma (FL) outcomes are heavily influenced by host immune activity with immune anti-tumor activity mitigated by PD-1/PD-L1 pathway engagement. Combination CD20-directed therapy plus PD-1 inhibition (PD-1i) increases T-cell tumor killing and NK-cell antibody-dependent cell cytotoxicity (ADCC). Mounting evidence supports immune-priming using PD-1i before cancer-directed agents.

View Article and Find Full Text PDF

: Solid organ transplant recipients (OTR) have been recently involved in exercise prescription programs in order to reduce the high prevalence of cardiovascular diseases. The normal systolic and diastolic cardiac function is fundamental to personalizing the prescription. Diastolic dysfunction can be associated to a higher risk of cardiovascular events and left atrial (LA) strain is an emerging parameter in the evaluation of diastolic compromising, especially in subjects with preserved ejection fraction.

View Article and Find Full Text PDF

[Artificial light at night effects glucose metabolism in the developing jawbone by inhibiting melatonin secretion].

Zhonghua Kou Qiang Yi Xue Za Zhi

January 2025

Department of Stomatology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology & School of Stomatology, Tongji Medical College, Huazhong University of Science and Technology & Hubei Province Key Laboratory of Oral and Maxillofacial Development and Regeneration, Wuhan 430022, China.

To investigate the effects of artificial light at night on the growth of mandibles in mice and its regulatory mechanisms. A mouse model of artificial light at night (night light pollution group) and normal lighting (normal light group) was established by controlling light exposure time, with 4 mice in each group. Micro-CT was employed to analyze the differences in bone quantities of the mandibles between the two groups.

View Article and Find Full Text PDF

Transmission-Based Monitoring of Dual-Applicator Microwave Ablation Discriminates Discontiguous from Contiguous Ablation Zones in an In Vivo Porcine Liver Model.

J Vasc Interv Radiol

January 2025

Department of Electrical and Computer Engineering, Kansas State University, Manhattan, KS 66506, USA; Department of Biomedical Engineering, The George Washington University, Washington, DC 20052, USA. Electronic address:

Purpose: To determine the technical feasibility of discriminating discontiguous from contiguous ablation zones between a pair of microwave ablation (MWA) applicators using broadband microwave transmission signal measurements in an in vivo porcine liver model.

Methods: Dual applicator 2.45GHz MWA was performed using one directional and one omnidirectional applicator, spaced 3cm apart, under imaging guidance.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!