A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of conventional IMRT and VMAT strategies for postmastectomy radiation therapy after immediate implant-based reconstruction using the new ESTRO-ACROP contouring guidelines. | LitMetric

This study evaluated the usability of conventional templates based on the new contour guidelines of the European Society of Radiation and Oncology and Advisory Committee in Radiation Oncology Practice (ESTRO-ACROP) for treatment plans of postmastectomy radiotherapy after immediate implant-based reconstruction. Intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) plans generated with two different treatment planning systems (TPSs, Eclipse and Monaco) were examined. Six computed tomography scans of patients aged 35-54 years were retrospectively analysed who had undergone mastectomy and breast reconstruction using silicone implants after being diagnosed with left breast cancer. Six radiation oncologists participated in this study, and each of them contoured the target volume of one left breast using conventional contour (CTV-CONV) and new contour (CTV-ESTRO) methods. This study showed that compared with CTV-CONV, using CTV-ESTRO with objectives and cost functions similar to those of TPSs worsened the target volume coverage and increased the total number of monitor units. Considering the organs at risk, CTV-ESTRO tended to increase the mean dose delivered to the contralateral lung. It is concluded that the approach used for the new ESTRO-ACROP contour method cannot be applied in a manner similar to that for the conventional breast contour method, implying that the new ESTRO-ACROP contour method may require more time for improving plans for a given treatment.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00411-024-01059-2DOI Listing

Publication Analysis

Top Keywords

contour method
12
radiation therapy
8
implant-based reconstruction
8
radiation oncology
8
left breast
8
target volume
8
estro-acrop contour
8
contour
6
radiation
5
evaluation conventional
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!