An improved phase generated carrier arctangent demodulation algorithm based on harmonic mixing and phase quadrature technology (PGC-Arctan-HP) is proposed in this paper, which can eliminate the effects of modulation depth shift, carrier phase delay, and light intensity disturbance (LID) on the demodulation results. The simulation results are consistent with theoretical analysis, and indicate that the PGC-Arctan-HP algorithm can achieve optimal demodulation compared with other demodulation algorithms. The results of interferometric experiments show that the demodulated waveforms of the improved algorithm are relatively stable with an amplitude error of 0.0294%. The total-harmonic-distortion (THD) and the signal-to-noise-and-distortion (SINAD) can reach -60.0286 dB and 59.5388 dB.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.506910DOI Listing

Publication Analysis

Top Keywords

demodulation algorithm
8
demodulation
5
improved pgc
4
pgc demodulation
4
algorithm
4
algorithm fiber
4
fiber optic
4
optic interferometric
4
interferometric sensors
4
sensors improved
4

Similar Publications

A wavelength demodulation method for ultra-short fiber Bragg grating (US-FBG) sensors based on an arrayed waveguide grating (AWG) and a convex optimization algorithm is proposed and demonstrated. Instead of measuring the output power ratio of the two adjacent AWG channels as previously done, in this work the wavelength demodulation is realized by reconstructing the US-FBG spectrum. The principle of spectral reconstruction involves using an AWG to sample the spectral information of US-FBG and constructing underdetermined matrix equations with the obtained prior information on transmission responses and the detected output power from multiple AWG channels.

View Article and Find Full Text PDF

Assessing the internal quality of fruits is crucial in food chemistry and quality control, and bruises on peaches can affect their edible value and storage life. However, the early detection of slight bruises in yellow peaches is a major challenge, as the symptoms of slight bruises are difficult to distinguish. Herein, this study aims to develop a more simple and efficient structured-illumination reflectance imaging system (SIRI) and algorithms for the early nondestructive detection of slight bruises in yellow peaches.

View Article and Find Full Text PDF

This paper proposes a novel seawater temperature sensor, to the best of our knowledge, that utilizes an optical microfiber coupler combined with a reflective silver mirror (OMCM). The sensor's sensitivity and durability are enhanced by encapsulating it in polydimethylsiloxane (PDMS). Additionally, a specially designed metal casing prevents the OMCM from responding to pressure, thus avoiding the challenge of multi-parameter demodulation and increasing its adaptability to harsh environments.

View Article and Find Full Text PDF

The scale factor of thermal sensitivity serves as a crucial performance metric for micro-electromechanical system (MEMS) gyroscopes, and is commonly employed to assess the temperature stability of inertial sensors. To improve the temperature stability of the scale factor of MEMS gyroscopes, a self-compensation method is proposed. This is achieved by integrating the primary and secondary relevant parameters of the scale factor using the partial least squares regression (PLSR) algorithm.

View Article and Find Full Text PDF

Multifrequency electrical impedance tomography (MFEIT) has shown great application prospects in the field of biomedical imaging. To realize high-precision multifrequency electrical impedance information acquisition, a high-precision MFEIT system with undersampling combined with a fast digital demodulation algorithm is proposed. The system is integrated with 16 electrodes, and semi-parallel acquisition is used.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!