Optical zoom is an essential function for many imaging systems including consumer electronics, biomedical microscopes, telescopes, and projectors. However, most optical zoom imaging systems have discrete zoom rates or narrow zoom ranges. In this work, a continuous optical zoom imaging system with a wide zoom range is proposed. It consists of a solid lens, two Alvarez lenses, and a camera with an objective. Each Alvarez lens is composed of two cubic phase plates, which have inverted freeform surfaces concerning each other. The movement of the cubic phase masks perpendicular to the optical axis is realized by the actuation of the dielectric elastomer. By applying actuation voltages to the dielectric elastomer, cubic phase masks are moved laterally and then the focal lengths of the two Alvarez lenses are changed. By adjusting the focal lengths of these two Alvarez lenses, the optical magnification is tuned. The proposed continuous optical zoom imaging system is built and the validity is verified by the experiments. The experimental results demonstrate that the zoom ratio is up to 10×, i.e., the magnification continuously changes from 1.58× to 15.80× when the lateral displacements of the cubic phase masks are about 1.0 mm. The rise and fall response times are 150 ms and 210 ms, respectively. The imaging resolution can reach 114 lp/mm during the optical zoom process. The proposed continuous optical imaging system is expected to be used in the fields of microscopy, biomedicine, virtual reality, etc.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.507056DOI Listing

Publication Analysis

Top Keywords

optical zoom
24
continuous optical
16
zoom imaging
16
alvarez lenses
16
cubic phase
16
imaging system
12
phase masks
12
zoom
10
optical
9
imaging systems
8

Similar Publications

Tungsten oxide (WO) electrochromic devices are obtaining increasing interest due to their color change and thermal regulation. However, most previous work focuses on the absorption or transmission spectra of materials, rather than the optical parameters evolution in full spectrum in the electrochromic processes. Herein, we developed a systematic protocol of ex situ methods to clarify the evolutions of subtle structure changes, Raman vibration modes, and optical parameters of WO thin films in electrochromic processes as stimulated by dosage-dependent Li insertion.

View Article and Find Full Text PDF

Precision autofocus in optical microscopy with liquid lenses controlled by deep reinforcement learning.

Microsyst Nanoeng

December 2024

School of Mechanical and Electrical Engineering, Soochow University, No.8 Jixue Road, Suzhou City, Jiangsu, 215000, China.

Microscopic imaging is a critical tool in scientific research, biomedical studies, and engineering applications, with an urgent need for system miniaturization and rapid, precision autofocus techniques. However, traditional microscopes and autofocus methods face hardware limitations and slow software speeds in achieving this goal. In response, this paper proposes the implementation of an adaptive Liquid Lens Microscope System utilizing Deep Reinforcement Learning-based Autofocus (DRLAF).

View Article and Find Full Text PDF

Application of digital tools and artificial intelligence in the Myasthenia Gravis Core Examination.

Front Neurol

December 2024

Department of Neurology & Rehabilitation Medicine, School of Medicine & Health Sciences, George Washington University, Washington, DC, United States.

Background: Advances in video image analysis and artificial intelligence provide opportunities to transform how patients are evaluated. In this study, we assessed the ability to quantify Zoom video recordings of a standardized neurological examination- the Myasthenia Gravis Core Examination (MG-CE)-designed for telemedicine evaluations.

Methods: We used Zoom (Zoom Video Communications) videos of patients with myasthenia gravis (MG) who underwent the MG-CE.

View Article and Find Full Text PDF

[Development and Clinical Application of High-Magnification Electronic Endoscope].

Zhongguo Yi Liao Qi Xie Za Zhi

November 2024

College of Optical Science and Engineering, Zhejiang University, Hangzhou, 310027.

This article introduces a high-magnification electronic endoscope system that utilizes a continuous zoom optical design, enabling high-magnification imaging at the cellular level. By selecting an appropriate initial retrofocus structure, the optimized modulation transfer function (MTF) curve of the zoom objective lens approaches the diffraction limit. Additionally, the tip and operation parts of the system incorporate modular gas-tight sealing and multiple layers of protective structure.

View Article and Find Full Text PDF

This paper introduces and analyzes a theory for a paraxial design of a hybrid catadioptric optical system with variable focal length, which uses focus tunable optical components. Compared to the conventional zoom lens system, the proposed hybrid optical system can be designed with a smaller length and weight than a lens system of similar characteristics. The hybrid system does not need the movement of individual elements for zooming.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!