Key Points: Adoption and extended time on peritoneal dialysis require patient input across a spectrum of needs, including automated PD (APD) device usability features that are less intimidating to patients and enable lifestyle advantages. Analysis of APD features critical to patients align with patient priorities identified in Standardized Outcomes in NephroloGy-PD: shorter setup time, mobility within the home, near silent operation, and modified APD size/orientation.

Background: Despite offering greater lifestyle benefits to patients with ESKD, adoption of peritoneal dialysis (PD) remains low globally, particularly among minorities and the socioeconomically disadvantaged. While automated PD (APD) affords a high potential for reducing the burden of KRT, understanding patient preferences is critical to guiding development of new and improved APD devices to better accommodate use in their daily lives.

Methods: A quantitative cross-sectional survey study was performed using adaptive conjoint analysis to quantify APD feature preferences among patients on PD, PD Registered Nurses (RNs), and non-PD patients to ascertain the relative importance of eight specific cycler attributes, including portability, noise, setup time, device size, setup directions, battery power, consumables, and PD RN control (PD RNs only), each with 2–3 descriptive feature levels.

Results: Forty-two patients on PD, 24 non-PD patients, and 52 PD RNs were surveyed. Preference shares spanned nearly the entire range from 0% to 100%, indicating strong preference discrimination. For all groups, “Portability in the Home,” “Noise Level,” and “Setup Time” were the most important features. Patients on PD gave highest priority to these features compared with other study participants, plausibly as features enabling improved lifestyle. A simulated “coat rack” style cycler with extended battery power that was easy to move in the home, silent, required only 10-minute setup, and had a fully animated instruction screen was preferred by all groups >90% compared with features present in existing cyclers.

Conclusions: Addressing APD cycler technical and therapy-related issues to improve usability, comfort, and convenience within the home may affect PD uptake and retention. Attention and priority must be given to patient-centric APD cycler design directed at including features that improve quality of life for the device end user.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11000714PMC
http://dx.doi.org/10.34067/KID.0000000000000377DOI Listing

Publication Analysis

Top Keywords

peritoneal dialysis
12
features
8
apd
8
automated apd
8
patients
8
setup time
8
non-pd patients
8
battery power
8
apd cycler
8
patient
4

Similar Publications

Aim: The diagnosis of sarcopenia in patients on peritoneal dialysis (PD) in clinics is limited owing to its relatively complicated process and the need for expensive assessment equipment. This study aimed to develop and validate sex-specific nomogram models based on body mass index (BMI), handgrip strength, and other routine follow-up examination indicators to predict sarcopenia in patients on PD.

Methods: From March 2023 to February 2024, 699 eligible patients were recruited from the PD centers of two tertiary hospitals in southeastern China.

View Article and Find Full Text PDF

The gut microbiota alterations interact with the pathogenesis and progression of chronic kidney disease (CKD). Probiotics have received wide attention as a potential management in CKD. We investigated the effects of Lactobacillus paracasei N1115 (LP N1115) on intestinal microbiota and related short-chain fatty acids (SCFAs) in end stage kidney disease patients on peritoneal dialysis (PD) in a single-center, prospective, randomized, double-blind, placebo-controlled study.

View Article and Find Full Text PDF

The electricity cost burden of durable medical equipment in the United States.

Sci Rep

December 2024

Paul H. O'Neill School of Public and Environmental Affairs, Indiana University, Bloomington, USA.

Those who rely on durable medical equipment (DME) for their health are more likely to be energy insecure and face higher energy burdens than those who do not. In this article, we evaluate the costs of electricity to run DMEs. We find that the average cost across the most common types of high-frequency DMEs-including oxygen concentrators, continuous positive airway pressure machines, and peritoneal kidney dialysis machines-is between $120 and $333 per year, depending on device size and usage frequency.

View Article and Find Full Text PDF

Purpose: With the increasing demand for dialysis, there is a growing emphasis on patient-centered care. This study investigated patients' satisfaction levels with peritoneal dialysis (PD) and hemodialysis (HD) care in Iran.

Methods: A cross-sectional multicenter study was conducted among 346 patients with chronic kidney disease (CKD) covered by the Iran Health Insurance Organization who received dialysis services from October to December 2022 across the country.

View Article and Find Full Text PDF

Trimethylamine -oxide (TMAO), a gut microbiome-derived metabolite, participates in the atherogenesis and vascular stiffening that is closely linked with cardiovascular (CV) complications and related deaths in individuals with kidney failure undergoing peritoneal dialysis (PD) therapy. In these patients, arterial stiffness (AS) is also an indicator of adverse CV outcomes. This study assessed the correlation between serum TMAO concentration quantified with high-performance liquid chromatography and mass spectrometry and central AS measured by carotid-femoral pulse wave velocity (cfPWV) in patients with chronic PD.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!