Allodynia is a neuropathic pain triggered by a normally painless stimulus: for example, a slight touch on the skin or slight sensation of hot or cold is extremely painful. Rehabilitation is long and uncertain. Protecting the painful area from stimuli is a priority of care. This type of care is complex and challenging for the care team: the pain caused in manufacturing a classic molded orthosis is unbearable for the patient, and the orthosis has a limited lifetime, and experience shows that it is not possible to produce two identical splints. The present study consisted in creating protective splints by 3D printing, designed from data collected with the 3D surface scanner used in our forensic imaging and anthropology unit. The pros and cons of the 3D orthosis versus standard molded orthoses from the point of view of the patient and the practitioner are discussed, with evaluation of related indications of this technology.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.hansur.2024.101646DOI Listing

Publication Analysis

Top Keywords

surface scanner
8
printed splint
4
splint designed
4
designed surface
4
scanner patients
4
patients hand
4
hand allodynia
4
allodynia allodynia
4
allodynia neuropathic
4
neuropathic pain
4

Similar Publications

Purpose: This study evaluated beam quality and radiation dosimetry of a CT scanner equipped with a novel detector and filtration technology called PureVision Optics (PVO). PVO features miniaturized electronics, a detector cut with microblade technology, and increased filtration in order to increase x-ray detection and reduce image noise.

Methods: We assessed the performance of two similar 320-detector CT scanners: one equipped with PVO and one without.

View Article and Find Full Text PDF

Dataset for developing deep learning models to assess crack width and self-healing progress in concrete.

Sci Data

January 2025

Department of Civil & Geotechnical Engineering and Geomechanics, AGH University of Krakow, al.Mickiewicza 30, 30-059, Krakow, Poland.

The presented dataset comes from an experimental study on the autogenous self-healing of high-strength concrete and the development of deep learning metasensor for crack width assessment and self-healing evaluation. Concrete specimens were prepared, matured, cracked, and exposed to self-healing. High-resolution scanning of the specimen surface and scale-invariant image processing were performed, multiple grid lines crossing cracks were established, and brightness degree profiles along grid lines were extracted.

View Article and Find Full Text PDF

Background/purpose: Different types of scanners are gradually used to produce digital dental casts in the current dental practice. This study tested the accuracy of the three desktop scanners and two intraoral scanners and evaluated whether the desktop scanners had higher precision than the intraoral scanners.

Materials And Methods: This study used the three desktop and two intraoral scanners to scan a standard dental cast 5 times.

View Article and Find Full Text PDF

Transient shear wave elastometry using a portable magnetic resonance sensor.

Magn Reson Med

January 2025

MRI Research Centre, Physics, University of New Brunswick, Fredericton, New Brunswick, Canada.

Purpose: Magnetic resonance elastography (MRE) provides detailed maps of tissue stiffness, helping to diagnose various health conditions, but requires the use of expensive clinical MRI scanners. Our approach utilizes compact, cost-effective portable MR sensors that offer bulk characterization of material properties in a region of interest close to the surface (within 1-2 cm). This accessible instrument could enable routine monitoring and prevention of diseases not readily evaluated with conventional tools.

View Article and Find Full Text PDF

Aims And Background: This study aimed to assess the accuracy of digital intraoral scans in capturing the three-dimensional (3D) surface of teeth and dental arches in mixed dentition, compared with conventional plaster models. Intraoral scanning technology has seen rapid advancements in recent years, revolutionizing orthodontic and dental practices. However, its accuracy in mixed dentition remains a subject of investigation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!