Purpose: Develop and evaluate the performance of a deep learning model (DLM) that forecasts eyes with low future visual field (VF) variability, and study the impact of using this DLM on sample size requirements for neuroprotective trials.

Design: Retrospective cohort and simulation study.

Methods: We included 1 eye per patient with baseline reliable VFs, OCT, clinical measures (demographics, intraocular pressure, and visual acuity), and 5 subsequent reliable VFs to forecast VF variability using DLMs and perform sample size estimates. We estimated sample size for 3 groups of eyes: all eyes (AE), low variability eyes (LVE: the subset of AE with a standard deviation of mean deviation [MD] slope residuals in the bottom 25th percentile), and DLM-predicted low variability eyes (DLPE: the subset of AE predicted to be low variability by the DLM). Deep learning models using only baseline VF/OCT/clinical data as input (DLM1), or also using a second VF (DLM2) were constructed to predict low VF variability (DLPE1 and DLPE2, respectively). Data were split 60/10/30 into train/val/test. Clinical trial simulations were performed only on the test set. We estimated the sample size necessary to detect treatment effects of 20% to 50% in MD slope with 80% power. Power was defined as the percentage of simulated clinical trials where the MD slope was significantly worse from the control. Clinical trials were simulated with visits every 3 months with a total of 10 visits.

Results: A total of 2817 eyes were included in the analysis. Deep learning models 1 and 2 achieved an area under the receiver operating characteristic curve of 0.73 (95% confidence interval [CI]: 0.68, 0.76) and 0.82 (95% CI: 0.78, 0.85) in forecasting low VF variability. When compared with including AE, using DLPE1 and DLPE2 reduced sample size to achieve 80% power by 30% and 38% for 30% treatment effect, and 31% and 38% for 50% treatment effect.

Conclusions: Deep learning models can forecast eyes with low VF variability using data from a single baseline clinical visit. This can reduce sample size requirements, and potentially reduce the burden of future glaucoma clinical trials.

Financial Disclosure(s): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ogla.2024.01.005DOI Listing

Publication Analysis

Top Keywords

sample size
24
low variability
24
deep learning
16
clinical trials
12
eyes low
12
learning models
12
variability
9
glaucoma clinical
8
low
8
visual field
8

Similar Publications

A series of CoFe2O4 materials derived from metal-organic framework were successfully constructed by the solvent-thermal method. The morphology of a typical sample CoFe2O4-1 was mostly in the form of a cubic rod-like structure with a size distribution of 3.2 ± 0.

View Article and Find Full Text PDF

Objectives: Distal femur fractures (DFF) are frequently treated surgically with single traditional constructs (STC), such as with a lateral plate or intramedullary nail, although nail-plate combination constructs (NPCC) are gaining attention. The purpose of this study is to compare outcomes between NPCC and STC for surgical fixation of DFF to guide surgeon decision-making.

Methods: Data Sources: This study is a systematic review and meta-analysis using PubMed, CINAHL, MEDLINE, Web of Science, Science Direct, and SPORTDiscus from database inception until January 10th, 2024.

View Article and Find Full Text PDF

The COVID-19 pandemic has a profound and lasting impact on the mental health of recovered individuals. To investigate the clinical risk factors associated with long-term post-traumatic stress symptoms (PTSS), anxiety, and depression in COVID-19 survivors, demographic information and medical records were collected during February 19 and March 20, 2020. Assessments of PTSS, anxiety, and depressive symptoms were conducted at two months (April to May 2020, Session 1) and two years (April to May 2022, Session 2) post-discharge.

View Article and Find Full Text PDF

The 2020 American Heart Association Guidelines advise not to perform mitral valve replacement (MVR) during septal myectomy (SM) to alleviate outflow obstruction. This study aims to review outcomes after concomitant mitral valve (MV) intervention versus SM alone. We conducted a comprehensive literature search across Embase, PubMed, and Scopus.

View Article and Find Full Text PDF

Liquid metal electrodes enabled cascaded on-chip dielectrophoretic separation of large-size-range particles.

Lab Chip

December 2024

State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, Beijing 100084, P. R. China.

The separation of large-size-range particles of complex biological samples is critical but yet well resolved. As a label-free technique, dielectrophoresis (DEP)-based particle separation faces the challenge of how to configure DEP in an integrated microfluidic device to bring particles of various sizes into the effective DEP force field. Herein, we propose a concept that combines the passive flow fraction mechanism with the accumulative DEP deflection effect in a cascaded manner.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!