Different printing technologies can be used for prosthetically oriented implant placement, however the influence of different printing orientations and steam sterilization remains unclear. In particular, no data is available for the novel technology Continuous Liquid Interface Production. The objective was to evaluate the dimensional accuracy of surgical guides manufactured with different printing techniques in vertical and horizontal printing orientation before and after steam sterilization. A total of 80 surgical guides were manufactured by means of continuous liquid interface production (CLIP; material: Keyguide, Keyprint), digital light processing (DLP; material: Luxaprint Ortho, DMG), stereolithography (SLA; Surgical guide, Formlabs), and fused filament fabrication (FFF; material: Clear Base Support, Arfona) in vertical and horizontal printing orientation (n = 10 per subgroup). Spheres were included in the design to determine the coordinates of 17 reference points. Each specimen was digitized with a laboratory scanner after additive manufacturing (AM) and after steam sterilization (134 °C). To determine the accuracy, root mean square values (RMS) were calculated and coordinates of the reference points were recorded. Based on the measured coordinates, deviations of the reference points and relevant distances were calculated. Paired t-tests and one-way ANOVA were applied for statistical analysis (significance p < 0.05). After AM, all printing technologies showed comparable high accuracy, with an increased deviation in z-axis when printed horizontally. After sterilization, FFF printed surgical guides showed distinct warpage. The other subgroups showed no significant differences regarding the RMS of the corpus after steam sterilization (p > 0.05). Regarding reference points and distances, CLIP showed larger deviations compared to SLA in both printing orientations after steam sterilization, while DLP manufactured guides were the most dimensionally stable. In conclusion, the different printing technologies and orientations had little effect on the manufacturing accuracy of the surgical guides before sterilization. However, after sterilization, FFF surgical guides exhibited significant deformation making their clinical use impossible. CLIP showed larger deformations due to steam sterilization than the other photopolymerizing techniques, however, discrepancies may be considered within the range of clinical acceptance. The influence on the implant position remains to be evaluated.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmbbm.2024.106418DOI Listing

Publication Analysis

Top Keywords

surgical guides
20
steam sterilization
20
reference points
16
continuous liquid
12
liquid interface
12
interface production
12
digital light
8
light processing
8
fused filament
8
filament fabrication
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!