A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Single isocenter versus dual isocenter treatment using flattening filter-free and jaw-tracking volumetrically modulated arc therapy for boot-shaped lung cancer: Evaluation of dosimetric and feasibility. | LitMetric

Background: To determine whether a dual-isocenter volumetrically modulated arc therapy (VMAT) technique results in lower normal pulmonary dosage compared to a traditional single isocenter technique for boot-shaped lung cancer.

Methods: A cohort of 15 patients with advanced peripheral or central lung cancer who had metastases in the mediastinum and supraclavicular lymph nodes was randomly selected for this retrospective study. VMAT plans were generated for each patient using two different beam alignment techniques with the 6-MV flattening filter-free (FFF) photon beam: single-isocenter jaw-tracking VMAT based on the Varian TrueBeam linear accelerator (S-TV), and dual-isocenter VMAT based on both TrueBeam (D-TV) and Halcyon linear accelerator (D-HV). For all 45 treatment plans, planning target volume (PTV) dose coverage, conformity/homogeneity index (CI/HI), mean heart dose (MHD), mean lung dose (MLD) and the total lung tissue receiving 5, 20, 30 Gy (V, V, V) were evaluated. The monitor units (MUs), delivery time, and plan quality assurance (QA) results were recorded.

Results: The quality of the objectives of the three plans was comparable to each other. In comparison with S-TV, D-TV and D-HV improved the CI and HI of the PTV (p < 0.05). The MLD was 13.84 ± 1.44 Gy (mean ± SD) for D-TV, 14.22 ± 1.30 Gy and 14.16 ± 1.42 Gy for S-TV and D-HV, respectively. Lungs-V was 50.78 ± 6.24%, 52.00 ± 7.32% and 53.36 ± 8.48%, Lungs-V was 23.72 ± 2.27%, 26.18 ± 2.86% and 24.96 ± 3.09%, Lungs-V30Gy was 15.69 ± 1.76%, 17.20 ± 1.72% and 16.52 ± 2.07%. Compared to S-TV, D-TV provided statistically significant better protection for the total lung, with the exception of the lungs-V. All plans passed QA according the gamma criteria of 3%/3 mm.

Conclusions: Taking into account the dosimetric results and published clinical data on radiation-induced pulmonary injury, dual-isocenter jaw-tracking VMAT may be the optimal choice for treating boot-shaped lung cancer.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11163486PMC
http://dx.doi.org/10.1002/acm2.14292DOI Listing

Publication Analysis

Top Keywords

single isocenter
8
flattening filter-free
8
volumetrically modulated
8
modulated arc
8
arc therapy
8
boot-shaped lung
8
lung cancer
8
vmat based
8
linear accelerator
8
lung
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!