AI Article Synopsis

  • * After 12 months, follow-up assessments of cognition and quality of life for 501 patients showed no differences among the oxygen target groups in overall cognitive function or related outcomes.
  • * Overall, the study indicates that for critically ill patients, the specific oxygen-saturation target set during ventilation does not influence long-term cognitive performance or quality of life measures.

Article Abstract

Among mechanically ventilated critically ill adults, the PILOT (Pragmatic Investigation of Optimal Oxygen Targets) trial demonstrated no difference in ventilator-free days among lower, intermediate, and higher oxygen-saturation targets. The effects on long-term cognition and related outcomes are unknown. To compare the effects of lower (90% [range, 88-92%]), intermediate (94% [range, 92-96%]), and higher (98% [range, 96-100%]) oxygen-saturation targets on long-term outcomes. Twelve months after enrollment in the PILOT trial, blinded neuropsychological raters conducted assessments of cognition, disability, employment status, and quality of life. The primary outcome was global cognition as measured using the Telephone Montreal Cognitive Assessment. In a subset of patients, an expanded neuropsychological battery measured executive function, attention, immediate and delayed memory, verbal fluency, and abstraction. A total of 501 patients completed follow-up, including 142 in the lower, 186 in the intermediate, and 173 in the higher oxygen target groups. Median (interquartile range) peripheral oxygen saturation values in the lower, intermediate, and higher target groups were 94% (91-96%), 95% (93-97%), and 97% (95-99%), respectively. Telephone Montreal Cognitive Assessment score did not differ between lower and intermediate (adjusted odds ratio [OR], 1.36 [95% confidence interval (CI), 0.92-2.00]), intermediate and higher (adjusted OR, 0.90 [95% CI, 0.62-1.29]), or higher and lower (adjusted OR, 1.22 [95% CI, 0.83-1.79]) target groups. There was also no difference in individual cognitive domains, disability, employment, or quality of life. Among mechanically ventilated critically ill adults who completed follow-up at 12 months, oxygen-saturation targets were not associated with cognition or related outcomes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10995564PMC
http://dx.doi.org/10.1164/rccm.202310-1826OCDOI Listing

Publication Analysis

Top Keywords

oxygen-saturation targets
16
mechanically ventilated
12
lower intermediate
12
intermediate higher
12
target groups
12
ventilated critically
8
critically ill
8
ill adults
8
cognition outcomes
8
disability employment
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!