Evolution of LC-MS/MS in clinical laboratories.

Clin Chim Acta

Department of Laboratory Medicine, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Science, Beijing, China. Electronic address:

Published: March 2024

Liquid chromatography-tandem mass spectrometry (LC-MS/MS) has attracted significant attention in clinical practice owing to its numerous advantages. However, the widespread adoption of this technique is hindered by certain limitations, such as inappropriate analyte selection, low levels of automation, and a lack of specific reference intervals and quality control programs. This review comprehensively summarizes the current challenges associated with LC-MS/MS and proposes potential resolutions. The principle of utility should guide the selection of biomarkers, prioritizing their practical value over sheer quantity. To achieve full-process automation, methodological innovation is crucial for developing high-throughput equipment. Establishing reference intervals for mass spectrometry-based assays across multiple centers and diverse populations is essential for accurate result interpretation. Additionally, the development of commercial quality control materials assumes pivotal importance in ensuring assay reliability and reproducibility. Harmonization and standardization efforts should focus on the development of reference methods and materials for the clinical use of LC-MS/MS. In the future, commercial assay kits and laboratory-developed tests (LDTs) are expected to coexist in clinical laboratories, each offering distinct advantages. The collaborative efforts of diverse professionals is vital for addressing the challenges associated with the clinical application of LC-MS/MS. The anticipated advancements include simplification, increased automation, intelligence, and the standardization of LC-MS/MS, ultimately facilitating its seamless integration into clinical routines for both technicians and clinicians.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cca.2024.117797DOI Listing

Publication Analysis

Top Keywords

clinical laboratories
8
reference intervals
8
quality control
8
challenges associated
8
clinical
6
lc-ms/ms
5
evolution lc-ms/ms
4
lc-ms/ms clinical
4
laboratories liquid
4
liquid chromatography-tandem
4

Similar Publications

Use of Albumin-Adjusted Calcium Measurements in Clinical Practice.

JAMA Netw Open

January 2025

Division of Endocrinology and Metabolism, Department of Medicine, University of Calgary, Calgary, Alberta, Canada.

Importance: Using albumin-adjusted calcium is commonly recommended for for measuring calcium, but with little empirical evidence to support the practice.

Objective: To assess the correlation between total calcium measurements (with or without adjustment) vs the ionized calcium level as a reference standard.

Design, Setting, And Participants: This was a population-based cross-sectional study in the province of Alberta, Canada, including adults tested for serum total calcium and ionized calcium simultaneously between January 1, 2013, and October 31, 2019.

View Article and Find Full Text PDF

Sex hormone-binding globulin (SHBG) regulates sex hormone availability and is influenced by metabolic factors. Variations in SHBG levels during pregnancy may affect the development of hypertensive disorders such as gestational hypertension (GH) and preeclampsia (PE). This systematic review and meta-analysis explores the potential of SHBG as a biomarker for predicting GH and PE.

View Article and Find Full Text PDF

encodes three regulatory subunits of class IA phosphoinositide 3-kinase (PI3K), each associating with any of three catalytic subunits, namely p110α, p110β, or p110δ. Constitutional mutations cause diseases with a genotype-phenotype relationship not yet fully explained: heterozygous loss-of-function mutations cause SHORT syndrome, featuring insulin resistance and short stature attributed to reduced p110α function, while heterozygous activating mutations cause immunodeficiency, attributed to p110δ activation and known as APDS2. Surprisingly, APDS2 patients do not show features of p110α hyperactivation, but do commonly have SHORT syndrome-like features, suggesting p110α hypofunction.

View Article and Find Full Text PDF

Background: Patients on maintenance hemodialysis (HD) face complications due to the accumulation of protein-bound uremic toxins, such as advanced glycation end products (AGEs), which contribute to inflammation, oxidative stress, and cardiovascular disease. Conventional HD techniques inadequately remove AGEs. This study evaluates the efficacy of the HA130 hemoadsorption cartridge combined with high-flux HD (HF-HD) in enhancing AGE removal.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!