Slow flow HD and traditional CDFI technologies in identifying pulmonary veins in the first trimester.

Arch Gynecol Obstet

Department of Key Laboratory of Birth Defect Prevention and Genetic Medicine of Shandong Health Commission, Maternal and Child Health Care Hospital of Shandong Province, Jinan, 250000, China.

Published: August 2024

Objective: This study aims to assess the feasibility and effectiveness of color doppler flow imaging (CDFI) technology and the Slow Flow HD imaging technique in identifying fetal pulmonary veins (PVs) in the first trimester (11-13 + 6 weeks), and further explore the factors affecting fetal pulmonary vein identification in early pregnancy.

Methods: Echocardiography and scanning of PVs were performed in 240 normal singleton fetuses in early pregnancy by using CDFI and slow flow HD techniques, to compare the ability of two methods to identify the PVs. Slow Flow HD technology was used to further investigate the difference of PVs identification at different gestational ages [group I (11-11 + 6 weeks), group II (12-12 + 6 weeks), group III (13-13 + 6 weeks)] and with different maternal body mass indices (BMI) (≥ 25 and < 25). In 31 cases of 240 fetuses, transvaginal ultrasonography was added due to maternal habitus or significant retroversion of the uterus, and the difference in PVs identification between transabdominal and transvaginal examination was analyzed.

Results: Successful PVs identification rates via CDFI and Slow Flow HD were 32.0% and 88.3%, respectively (p < 0.05). The identification rate of at least one and two pulmonary veins in Slow Flow HD was 88.3% and 76.2%, and all four pulmonary veins in 11.6% (p < 0.05). The identification rate of group I, II and III were 76.4%, 88.9% and 96.0%, respectively. The identification rate was 45.1% in the transabdominal ultrasound group and 83.8% in the transvaginal ultrasound group. The identification rate was 62.5% in the BMI ≥ 25 group and 94.7% in the BMI < 25 group (p < 0.05).

Conclusions: Slow Flow HD can detect PVs in early pregnancy more often than using CDFI. Slow Flow HD is a feasible and effective imaging technique for evaluating PVs in early pregnancy.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00404-023-07352-7DOI Listing

Publication Analysis

Top Keywords

slow flow
16
pulmonary veins
8
flow imaging
8
fetal pulmonary
8
slow
4
flow traditional
4
traditional cdfi
4
cdfi technologies
4
technologies identifying
4
identifying pulmonary
4

Similar Publications

Vertical flow immunoassay for multiplex mycotoxins based on photonic nitrocellulose and SERS nanotags.

Food Chem X

January 2025

State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China.

Here, we report a SERS based VFA using PNC as a sensing substrate for highly sensitive multiplex mycotoxins detection. The PNC was fabricated by filtration-based self-assembled monodisperse SiO NPs on a filter membrane as a template, and the obtained PNC had an ordered complementary inverse opal structure. In parallel, three kinds of Raman dyes encoding Au@Ag, Au@Ag and Au@Ag SERS nanotags were synthesized for the detection of OTA, AFB1 and ZON.

View Article and Find Full Text PDF

A 36-year-old woman with a history of neck swelling was diagnosed with papillary thyroid carcinoma, a common but typically slow-growing thyroid cancer with a good prognosis. Despite frequent lymph node metastasis, mortality rates are low. This cancer can rarely spread to unusual areas like the axillary region.

View Article and Find Full Text PDF

Objective: The complex mix of factors, including hemodynamic forces and wall remodeling mechanisms, that drive intracranial aneurysm growth is unclear. This study focuses on the specific regions within aneurysm walls where growth occurs and their relationship to the prevalent hemodynamic conditions to reveal critical mechanisms leading to enlargement.

Methods: The authors examined hemodynamic models of 67 longitudinally followed aneurysms, identifying 88 growth regions.

View Article and Find Full Text PDF

Background: Chordoma, characterized as a slow growing yet locally invasive and destructive bone tumor mainly emerging in the sacrum and clivus, presents a unique challenge due to its rarity, hampering the development of effective treatment strategies. Comprehensive understanding of tumor biology is crucial to suggest novel treatment modalities. Reactive oxygen species (ROS), a family of chemically reactive and unstable oxygen derivatives, are controlled by an intracellular antioxidant system to maintain homeostasis.

View Article and Find Full Text PDF

Conventional techniques for evaluating hydration status include the analysis of blood, urine, and body weight. Recently, advancements in dentistry have introduced capacitance sensor-based oral epithelial moisture meters as promising avenues for assessment. This study aimed to examine the correlation between oral mucosal moisture content, as determined using a capacitance sensor, and exercise-induced dehydration.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!