In environmental analysis, the detection of water-soluble synthetic polymers (WSSP) presents considerable challenges. Thus, a precise and reproducible analytical method was developed using continuous-flow off-line pyrolysis with gas chromatography/mass spectrometry (GC/MS) to simultaneously identify multiple water-soluble polymers from a single environmental sample. WSSP are widely used in multiple industries as hydrogels due to their hydrophilic character and potential biocompatibility. This adaptability of hydrogels is reflected in their ability to provide customized formulations for specific needs, such as in the development of personal care products, medicine, and pharmaceuticals. Specifically, polyvinylpyrrolidone (PVP), poly(N-vinylcaprolactam) (PNVCL), and polyethyleneimine (PEI) were targeted for analysis in wastewater, employing unique pyrolysis products for identification. These polymers require careful assessment in wastewater to evaluate potential environmental risks associated with their release. PVP and PNVCL were identified through two pyrolysis products, while six pyrolysis products were utilized for the identification of PEI. The validated method demonstrated very good linearity and reproducibility, with correlation coefficients ranging from 0.94 to 0.99 and relative standard deviation (RSD) values between 3 % and 36 % for the targeted compounds. The limit of quantification (LOQ) for the three polymers ranged from 1 to 10 μg L-1. Moreover, the average recovery rates for these polymers, determined from artificial water samples, were approx. 85 %. Utilizing the validated method, water samples from seven wastewater treatment plants in Germany were successfully analyzed, confirming the presence of these polymers at elevated concentrations in the μg L-1 range. Notably, untreated influent waters exhibited higher polymer levels compared to treated influents and effluents, underscoring their significant contribution to overall polymer content. The developed analytical method provides an efficient tool for the simultaneous identification and quantification of PVP, PNVCL, and PEI in wastewater samples. The results highlighted the prevalent presence of PVP, PNVCL, and PEI in the tested wastewater samples, indicating their significant abundance.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.scitotenv.2024.170320DOI Listing

Publication Analysis

Top Keywords

pvp pnvcl
16
pnvcl pei
12
wastewater samples
12
pyrolysis products
12
simultaneous identification
8
identification quantification
8
water-soluble polymers
8
pei wastewater
8
continuous-flow off-line
8
off-line pyrolysis
8

Similar Publications

In environmental analysis, the detection of water-soluble synthetic polymers (WSSP) presents considerable challenges. Thus, a precise and reproducible analytical method was developed using continuous-flow off-line pyrolysis with gas chromatography/mass spectrometry (GC/MS) to simultaneously identify multiple water-soluble polymers from a single environmental sample. WSSP are widely used in multiple industries as hydrogels due to their hydrophilic character and potential biocompatibility.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!