Objective: We sought to develop and validate the Crohn's Disease-Health Index (CD-HI), a disease-specific, patient-reported outcome measure that serially measures Crohn's disease (CD) symptomatic burden in adults with CD.

Background: As therapeutic interventions are tested among patients with CD, responsive outcome measures are needed to track disease progression and therapeutic gain during clinical trials.

Patients And Methods: We conducted a national cross-sectional study of individuals with CD to identify the most prevalent and impactful symptoms of CD. The most relevant symptoms were included in the CD-HI. We used factor analysis, qualitative patient interviews, test-retest reliability evaluation, and known group validity testing to evaluate and optimize the CD-HI.

Results: The CD-HI contains 12 subscales that comprehensively measure CD burden using the patient's perspective. Fifteen adults with CD beta tested the CD-HI and found the instrument to be clear, easy to use, and relevant to them. Twenty-three adults with CD participated in an assessment of test-retest reliability, which indicated high reliability of individual questions, subscales, and the full instrument (intraclass correlation coefficient = 0.84 for the full instrument). The CD-HI and its subscales demonstrated a high internal consistency (Cronbach α = 0.98 for the full instrument). The CD-HI distinguished between groups of individuals with CD known to differ in disease severity.

Conclusions: This research supports the use of the CD-HI as a valid, sensitive, reliable, and relevant patient-reported outcome to determine the multifactorial disease burden of those with CD, assess the relevance and merit of future CD therapies, and support drug labeling claims.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11465757PMC
http://dx.doi.org/10.1097/MCG.0000000000001976DOI Listing

Publication Analysis

Top Keywords

full instrument
12
crohn's disease-health
8
outcome measure
8
patient-reported outcome
8
test-retest reliability
8
cd-hi subscales
8
instrument cd-hi
8
cd-hi
7
disease-health development
4
development evaluation
4

Similar Publications

Validation of Aerobic Capacity (VO2max) and Pulse Oximetry in Wearable Technology.

Sensors (Basel)

January 2025

School of Integrated Health Sciences, Department of Kinesiology and Nutrition Sciences, University of Nevada, Las Vegas, NV 89154, USA.

Introduction: As wearable technology becomes increasingly popular and sophisticated, independent validation is needed to determine its accuracy and potential applications. Therefore, the purpose of this study was to evaluate the accuracy (validity) of VO2max estimates and blood oxygen saturation measured via pulse oximetry using the Garmin fēnix 6 with a general population participant pool.

Methods: We recruited apparently healthy individuals (both active and sedentary) for VO2max (n = 19) and pulse oximetry testing (n = 22).

View Article and Find Full Text PDF

Forward modeling the magnetic effects of an inferred source is the basis of magnetic anomaly inversion for estimating subsurface magnetization parameters. This study uses numerical least-squares Gauss-Legendre quadrature (GLQ) integration to evaluate the magnetic potential, anomaly, and gradient components of a cylindrical prism element. Relative to previous studies, it quantifies for the first time the magnetic gradient components, enabling their applications in the interpretation of cylindrical bodies.

View Article and Find Full Text PDF

Background: The concept of children's rights emerged during the 1980s and emphasised the role of children as active participants in matters which concern them.

Aim: This review aims to identify and synthesise the empirical evidence base on healthcare professionals' (HCPs) understanding of children's rights.

Methods: Five electronic databases (PubMed, CINAHL, Embase, PsycINFO, and the Web of Science) were systematically searched in May 2023.

View Article and Find Full Text PDF

Comparison of bioabsorbable screw versus metallic screw fixation for tibial tubercle fractures in adolescents: a retrospective cohort study.

BMC Musculoskelet Disord

January 2025

Department of Orthopedics, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, 100045, China.

Background: Displaced tibial tubercle (TT) fractures in adolescents are typically treated with open reduction and internal fixation. While metallic screw (MS) fixation provides strong stability, it often results in a high incidence of postoperative screw head protrusion or irritation, leading to additional removal surgery. Bioabsorbable screw (BS) fixation presents an alternative that may avoid these issues, though its stability has not yet been extensively documented in the literature.

View Article and Find Full Text PDF

Background: Endotracheal intubation (ETI) is a life-saving procedure that must be accurately carried on to guard against complications. Presbyopia leads to difficulty in viewing close objects and may obstacle proper intubation even with the best hands.

Purpose: This study supposed that the use of video-laryngoscope (VL) may provide better intubation conditions for presbyopic anesthetists and targets to evaluate the neonates and infants' intubation success rates (ISR) by anesthetists aged ≥ 45 years using the C-MAC VL compared to the standard laryngoscope (SL).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!